Event Notification Report for March 04, 1999
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
03/03/1999 - 03/04/1999
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 35438
Facility: CATAWBA
Region: 2 State: SC
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: BILL RUDD
HQ OPS Officer: FANGIE JONES
Region: 2 State: SC
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: BILL RUDD
HQ OPS Officer: FANGIE JONES
Notification Date: 03/04/1999
Notification Time: 01:15 [ET]
Event Date: 03/04/1999
Event Time: 00:28 [EST]
Last Update Date: 05/05/1999
Notification Time: 01:15 [ET]
Event Date: 03/04/1999
Event Time: 00:28 [EST]
Last Update Date: 05/05/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
10 CFR Section:
50.72(b)(1)(ii)(B) - OUTSIDE DESIGN BASIS
Person (Organization):
CAUDLE JULIAN (R2)
CAUDLE JULIAN (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | N | Y | 100 | Power Operation | 100 | Power Operation |
IMPROVED TECHNICAL SPECIFICATION REVIEW FOUND SUSPECT SURVEILLANCE.
The licensee identified a suspect surveillance during a programmatic review of Improved Technical Specifications Surveillances. The surveillance involved the timers for the hydrogen skimmer suction isolation valves. The acceptance criteria in the surveillance procedure was higher than allowed by the acceptance criteria of Updated Final Safety Analysis Report Table 7-15. The licensee entered LCO 3.0.3 due to both trains being out of tolerance. The licensee exited LCO 3.0.3 at 0059 EST after one of the timers was recalibrated and that train was declared operable.
The licensee also verified that the Unit 1 hydrogen skimmer suction valve timers were in specification. One of Unit 1's valves was out of specification and will be reported as a 30-day written report.
The licensee notified the NRC resident inspector.
* * * RETRACTION AT 0931 ON 05/05/99 FROM RUDD TAKEN BY STRANSKY * * *
"After further review and evaluation, Engineering determined that the Hydrogen Skimmer System would have operated within the response time limits specified in the Technical Specifications and the Updated Final Safety Analysis Report. As a result, both trains of the Unit 2 Hydrogen Skimmer System were operable, and the unit was never outside of its design basis. Therefore, Catawba is withdrawing the ENS notification for this event."
The NRC resident inspector has been informed of this retraction. The HOO notified the R2DO (Christensen).
The licensee identified a suspect surveillance during a programmatic review of Improved Technical Specifications Surveillances. The surveillance involved the timers for the hydrogen skimmer suction isolation valves. The acceptance criteria in the surveillance procedure was higher than allowed by the acceptance criteria of Updated Final Safety Analysis Report Table 7-15. The licensee entered LCO 3.0.3 due to both trains being out of tolerance. The licensee exited LCO 3.0.3 at 0059 EST after one of the timers was recalibrated and that train was declared operable.
The licensee also verified that the Unit 1 hydrogen skimmer suction valve timers were in specification. One of Unit 1's valves was out of specification and will be reported as a 30-day written report.
The licensee notified the NRC resident inspector.
* * * RETRACTION AT 0931 ON 05/05/99 FROM RUDD TAKEN BY STRANSKY * * *
"After further review and evaluation, Engineering determined that the Hydrogen Skimmer System would have operated within the response time limits specified in the Technical Specifications and the Updated Final Safety Analysis Report. As a result, both trains of the Unit 2 Hydrogen Skimmer System were operable, and the unit was never outside of its design basis. Therefore, Catawba is withdrawing the ENS notification for this event."
The NRC resident inspector has been informed of this retraction. The HOO notified the R2DO (Christensen).
Other Nuclear Material
Event Number: 35439
Rep Org: WITTNAUER WORLDWIDE, L.P.
Licensee: WITTNAUER WORLDWIDE, L.P.
Region: 0
City: Cayey State: PR
County:
License #: 52-19336-01
Agreement: N
Docket:
NRC Notified By: Kelvin Massey
HQ OPS Officer: JOHN MacKINNON
Licensee: WITTNAUER WORLDWIDE, L.P.
Region: 0
City: Cayey State: PR
County:
License #: 52-19336-01
Agreement: N
Docket:
NRC Notified By: Kelvin Massey
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/04/1999
Notification Time: 14:18 [ET]
Event Date: 03/04/1999
Event Time: 14:18 [EST]
Last Update Date: 03/04/1999
Notification Time: 14:18 [ET]
Event Date: 03/04/1999
Event Time: 14:18 [EST]
Last Update Date: 03/04/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
10 CFR Section:
20.2201(a)(1)(ii) - LOST/STOLEN LNM>10X
Person (Organization):
CAUDLE JULIAN (R2)
WAYNE HODGES (NMSS)
CAUDLE JULIAN (R2)
WAYNE HODGES (NMSS)
UNACCOUNTED TRITIUM
Event was reported by Wittnauer Worldwide, L.P., located in Cayey, Puerto Rico.
NRC Region 2 conducted and inspection of Wittnauer Worldwide, L.P. on October 26, 1998. On January 22, 1999, Wittnauer Worldwide, L.P. received an inspection report from the US NRC containing two violations involving missing radioactive material (tritium). On March 3, 1999, the licensee sent a response to the NRC Region 2 addressing the violations.
The licensee reported missing 0.27 curies of tritium for the month of November, 1997; 0.29 curies for December, 1997; 0.34 curies for the month of January, 1998; 0.41 curies for the month of February, 1998; 0.31 curies for the month of August, 1998; and 0.42 curies for the month of September, 1998.
The licensee believes that the missing tritium , which is used on watch hands, was used to replace old watch hands (the tritium was not accounted for when the new watch hands were used to replace old watch hands on watches that were being repaired).
Wittnauer Worldwide, L.P. acquired the watch company in December, 1996.
NRC Region 2 (Mark Lesser) has been following this event.
Event was reported by Wittnauer Worldwide, L.P., located in Cayey, Puerto Rico.
NRC Region 2 conducted and inspection of Wittnauer Worldwide, L.P. on October 26, 1998. On January 22, 1999, Wittnauer Worldwide, L.P. received an inspection report from the US NRC containing two violations involving missing radioactive material (tritium). On March 3, 1999, the licensee sent a response to the NRC Region 2 addressing the violations.
The licensee reported missing 0.27 curies of tritium for the month of November, 1997; 0.29 curies for December, 1997; 0.34 curies for the month of January, 1998; 0.41 curies for the month of February, 1998; 0.31 curies for the month of August, 1998; and 0.42 curies for the month of September, 1998.
The licensee believes that the missing tritium , which is used on watch hands, was used to replace old watch hands (the tritium was not accounted for when the new watch hands were used to replace old watch hands on watches that were being repaired).
Wittnauer Worldwide, L.P. acquired the watch company in December, 1996.
NRC Region 2 (Mark Lesser) has been following this event.
Power Reactor
Event Number: 35440
Facility: CALLAWAY
Region: 4 State: MO
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: DAVID FITZGERALD
HQ OPS Officer: JOHN MacKINNON
Region: 4 State: MO
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: DAVID FITZGERALD
HQ OPS Officer: JOHN MacKINNON
Notification Date: 03/04/1999
Notification Time: 15:23 [ET]
Event Date: 03/04/1999
Event Time: 11:54 [CST]
Last Update Date: 03/04/1999
Notification Time: 15:23 [ET]
Event Date: 03/04/1999
Event Time: 11:54 [CST]
Last Update Date: 03/04/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
10 CFR Section:
73.71(b)(1) - SAFEGUARDS REPORTS
Person (Organization):
PHIL HARRELL (R4)
PHIL HARRELL (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 100 | Power Operation |
SAFEGUARDS SYSTEM DEGRADATION RELATED TO AREA BOUNDARY. IMMEDIATE COMPENSATORY MEASURES TAKEN UPON DISCOVERY.
The licensee has notified the NRC resident inspector.
Contact the HOO for additional details.
The licensee has notified the NRC resident inspector.
Contact the HOO for additional details.