Event Notification Report for February 27, 1999
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
02/26/1999 - 02/27/1999
EVENT NUMBERS
35421354193541735418
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 35421
Facility: VOGTLE
Region: 2 State: GA
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: CHUCK MEYER
HQ OPS Officer: DICK JOLLIFFE
Region: 2 State: GA
Unit: [1] [] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: CHUCK MEYER
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 02/28/1999
Notification Time: 03:14 [ET]
Event Date: 02/27/1999
Event Time: 23:40 [EST]
Last Update Date: 03/15/1999
Notification Time: 03:14 [ET]
Event Date: 02/27/1999
Event Time: 23:40 [EST]
Last Update Date: 03/15/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
ROBERT HAAG (R2)
ROBERT HAAG (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | M/R | Y | 18 | Power Operation | 0 | Hot Standby |
-MAN Rx TRIP FROM 18% DUE TO NUCLEAR INSTRUMENTS ANOMALY DURING PLANT SHUTDOWN-
WHILE SHUTTING UNIT 1 DOWN FOR A PLANNED REFUELING OUTAGE, CONTROL ROOM OPERATORS MANUALLY TRIPPED UNIT 1 FROM 18% POWER DUE TO A CONCERN THAT THE NUCLEAR INSTRUMENTS INTERMEDIATE RANGE FLUX TRIP WOULD NOT RESET BEFORE THE POWER RANGE (P-10) AUTO UNBLOCK OCCURRED. ALL CONTROL RODS INSERTED COMPLETELY. NO SAFETY OR RELIEF VALVES LIFTED. CONTROL ROOM OPERATORS MANUALLY ACTUATED THE AUXILIARY FEEDWATER SYSTEM TO MAINTAIN STEAM GENERATORS AT THEIR NORMAL WATER LEVELS. UNIT 1 IS STABLE IN MODE 3 (HOT STANDBY). THE LICENSEE PLANS TO INVESTIGATE THE CAUSE OF THE NUCLEAR INSTRUMENTS ANOMALY AND PROCEED WITH THE PLANNED REFUELING OUTAGE.
THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.
* * * RETRACTION AT 1455 ON 03/15/1999 FROM BILL DUNN TAKEN BY STRANSKY
"Although the normal method of entry into a refueling outage involves gradually driving control rods to 0% power, operators performed a manual reactor trip from 18% power, as allowed by plant procedures. At the end of the current fuel cycle, neutron flux distribution flattened compared to the beginning of cycle flux shape. Plant operators had been advised that, during shutdown, an intermediate range (IR) neutron flux trip setpoint may not reset prior to unblocking the IR trip signal at the P-10 reset setpoint. Operators had been reminded that procedures allow a manual trip of the unit if this condition occurred. When the predicted IR neutron flux reset did not occur as power was reduced to 18%, a manual reactor trip was performed."
"Because the manual trip that occurred was anticipated, pre-job briefings were held and because it was addressed in the procedure involved, it does not meet the criteria for reporting per 10 CFR 50.72 or 10 CFR 50.73. The trip was part of a pre-planned activity, and therefore, the previous notification is hereby retracted."
The NRC resident inspector has been informed of this retraction by the licensee. The NRC operations officer notified the R2DO (McAlpine).
WHILE SHUTTING UNIT 1 DOWN FOR A PLANNED REFUELING OUTAGE, CONTROL ROOM OPERATORS MANUALLY TRIPPED UNIT 1 FROM 18% POWER DUE TO A CONCERN THAT THE NUCLEAR INSTRUMENTS INTERMEDIATE RANGE FLUX TRIP WOULD NOT RESET BEFORE THE POWER RANGE (P-10) AUTO UNBLOCK OCCURRED. ALL CONTROL RODS INSERTED COMPLETELY. NO SAFETY OR RELIEF VALVES LIFTED. CONTROL ROOM OPERATORS MANUALLY ACTUATED THE AUXILIARY FEEDWATER SYSTEM TO MAINTAIN STEAM GENERATORS AT THEIR NORMAL WATER LEVELS. UNIT 1 IS STABLE IN MODE 3 (HOT STANDBY). THE LICENSEE PLANS TO INVESTIGATE THE CAUSE OF THE NUCLEAR INSTRUMENTS ANOMALY AND PROCEED WITH THE PLANNED REFUELING OUTAGE.
THE LICENSEE INFORMED THE NRC RESIDENT INSPECTOR.
* * * RETRACTION AT 1455 ON 03/15/1999 FROM BILL DUNN TAKEN BY STRANSKY
"Although the normal method of entry into a refueling outage involves gradually driving control rods to 0% power, operators performed a manual reactor trip from 18% power, as allowed by plant procedures. At the end of the current fuel cycle, neutron flux distribution flattened compared to the beginning of cycle flux shape. Plant operators had been advised that, during shutdown, an intermediate range (IR) neutron flux trip setpoint may not reset prior to unblocking the IR trip signal at the P-10 reset setpoint. Operators had been reminded that procedures allow a manual trip of the unit if this condition occurred. When the predicted IR neutron flux reset did not occur as power was reduced to 18%, a manual reactor trip was performed."
"Because the manual trip that occurred was anticipated, pre-job briefings were held and because it was addressed in the procedure involved, it does not meet the criteria for reporting per 10 CFR 50.72 or 10 CFR 50.73. The trip was part of a pre-planned activity, and therefore, the previous notification is hereby retracted."
The NRC resident inspector has been informed of this retraction by the licensee. The NRC operations officer notified the R2DO (McAlpine).
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 35419
Facility: FITZPATRICK
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: STEVE CAROLIN
HQ OPS Officer: BOB STRANSKY
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] GE-4
NRC Notified By: STEVE CAROLIN
HQ OPS Officer: BOB STRANSKY
Notification Date: 02/27/1999
Notification Time: 22:39 [ET]
Event Date: 02/27/1999
Event Time: 21:56 [EST]
Last Update Date: 03/01/1999
Notification Time: 22:39 [ET]
Event Date: 02/27/1999
Event Time: 21:56 [EST]
Last Update Date: 03/01/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(1)(vi) - INTERNAL THREAT
10 CFR Section:
50.72(b)(1)(vi) - INTERNAL THREAT
Person (Organization):
RICHARD BARKLEY (R1)
RICHARD BARKLEY (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 100 | Power Operation | 65 | Power Operation |
FIRE ONSITE LASTING LESS THAN 10 MINUTES
At 2156, the 'A' circulating water pump tripped, and the control room received indication of a fire in the pump motor. The onsite fire brigade responded, and the fire was extinguished at 2204. The licensee reported that the pump motor does not appear to be extensively damaged and that no other equipment was involved in the fire. Reactor power was reduced to 65% of rated due to the unavailability of the circulating water pump. No personnel injuries were reported.
The licensee will inform the NRC resident inspector of this event.
******************** UPDATE AT 1129 ON 03/01/99 FROM BOB STEIGERWALD TO TROCINE ********************
The following text is a portion of a facsimile received from the licensee:
"This notification retracts an earlier report made February 27, 1999, at 2156, per 10CFR50.72(b)(1)(vi), due to a fire in the 'A' circulating water pump motor junction box. The motor was de-energized, and the fire was extinguished within 10 minutes. The emergency plan was not entered. The fire did not affect the ability of plant personnel in the performance of duties required for safe operation of the plant."
"The reporting criteria for fires is based on events that endanger the safety of the plant or interfere with personnel in the performance of duties necessary for safe plant operations. This was a small fire in a motor junction box, located in the non-safety-related area of the screenwell, that was extinguished when the motor was de-energized. Safe plant operation was not affected by the event. Therefore, the 10CFR50.72(b)(1)(vi) event notification is being retracted."
The licensee notified the NRC resident inspector. The NRC operations officer notified the R1DO (Modes).
At 2156, the 'A' circulating water pump tripped, and the control room received indication of a fire in the pump motor. The onsite fire brigade responded, and the fire was extinguished at 2204. The licensee reported that the pump motor does not appear to be extensively damaged and that no other equipment was involved in the fire. Reactor power was reduced to 65% of rated due to the unavailability of the circulating water pump. No personnel injuries were reported.
The licensee will inform the NRC resident inspector of this event.
******************** UPDATE AT 1129 ON 03/01/99 FROM BOB STEIGERWALD TO TROCINE ********************
The following text is a portion of a facsimile received from the licensee:
"This notification retracts an earlier report made February 27, 1999, at 2156, per 10CFR50.72(b)(1)(vi), due to a fire in the 'A' circulating water pump motor junction box. The motor was de-energized, and the fire was extinguished within 10 minutes. The emergency plan was not entered. The fire did not affect the ability of plant personnel in the performance of duties required for safe operation of the plant."
"The reporting criteria for fires is based on events that endanger the safety of the plant or interfere with personnel in the performance of duties necessary for safe plant operations. This was a small fire in a motor junction box, located in the non-safety-related area of the screenwell, that was extinguished when the motor was de-energized. Safe plant operation was not affected by the event. Therefore, the 10CFR50.72(b)(1)(vi) event notification is being retracted."
The licensee notified the NRC resident inspector. The NRC operations officer notified the R1DO (Modes).
Power Reactor
Event Number: 35417
Facility: CRYSTAL RIVER
Region: 2 State: FL
Unit: [3] [] []
RX Type: [3] B&W-L-LP
NRC Notified By: LARRY MOFFATT
HQ OPS Officer: DICK JOLLIFFE
Region: 2 State: FL
Unit: [3] [] []
RX Type: [3] B&W-L-LP
NRC Notified By: LARRY MOFFATT
HQ OPS Officer: DICK JOLLIFFE
Notification Date: 02/27/1999
Notification Time: 09:07 [ET]
Event Date: 02/27/1999
Event Time: 08:10 [EST]
Last Update Date: 02/27/1999
Notification Time: 09:07 [ET]
Event Date: 02/27/1999
Event Time: 08:10 [EST]
Last Update Date: 02/27/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
ROBERT HAAG (R2)
ROBERT HAAG (R2)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 3 | N | Y | 100 | Power Operation | 100 | Power Operation |
- STATE NOTIFIED OF A KEMP'S RIDLEY SEA TURTLE RETRIEVED FROM THE PLANT INTAKE WATER -
At 2232 on 02/26/99, a young Kemp's Ridley sea turtle was taken from the water at the intake of Crystal River Unit 3. The turtle was found pinned against the bar rack and was retrieved by site personnel in accordance with the Florida Power Corporation Turtle Protection Guidelines. Crystal River Mariculture Center personnel took custody of the sea turtle and will return it to the Gulf of Mexico In the afternoon of 02/27/99. At 0810 on 02/27/99, the Florida Department of Environmental Protection was notified of the retrieval of the sea turtle.
The licensee notified the NRC Resident Inspector.
At 2232 on 02/26/99, a young Kemp's Ridley sea turtle was taken from the water at the intake of Crystal River Unit 3. The turtle was found pinned against the bar rack and was retrieved by site personnel in accordance with the Florida Power Corporation Turtle Protection Guidelines. Crystal River Mariculture Center personnel took custody of the sea turtle and will return it to the Gulf of Mexico In the afternoon of 02/27/99. At 0810 on 02/27/99, the Florida Department of Environmental Protection was notified of the retrieval of the sea turtle.
The licensee notified the NRC Resident Inspector.
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
!!!!! THIS EVENT HAS BEEN RETRACTED !!!!!
Power Reactor
Event Number: 35418
Facility: GINNA
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: DOUGLAS GOMEZ
HQ OPS Officer: BOB STRANSKY
Region: 1 State: NY
Unit: [1] [] []
RX Type: [1] W-2-LP
NRC Notified By: DOUGLAS GOMEZ
HQ OPS Officer: BOB STRANSKY
Notification Date: 02/27/1999
Notification Time: 13:37 [ET]
Event Date: 02/27/1999
Event Time: 11:39 [EST]
Last Update Date: 03/03/1999
Notification Time: 13:37 [ET]
Event Date: 02/27/1999
Event Time: 11:39 [EST]
Last Update Date: 03/03/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
RICHARD BARKLEY (R1)
RICHARD BARKLEY (R1)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | Y | 70 | Power Operation | 70 | Power Operation |
CONTAINMENT VENTILATION ISOLATION DURING I&C WORK ON RADIATION MONITOR
"During Instrument and Control (I/C) activities on radiation channel R-12, an unexpected Containment Ventilation Isolation (CVI) occurred. The planning activities for this maintenance recognized the potential of generating a CVI signal and directed the technicians to install a jumper to prevent the actuation. Even with the jumper installed an unexpected CVI occurred when the R-12 drawer was deenergized. The CVI was therefore due to maintenance activities and was not the result of an actual high radiation condition.
"No plant system other than the containment ventilation monitoring system was affected by this event. The plant is stable at approximately 70% power with a plant coastdown in progress.
"This event is reportable under lOCFR50.72(b)(2)(ii), 'Any condition that results in a manual or automatic actuation an Engineered Safety Feature.'"
The NRC resident inspector has been informed of this notification.
* * * RETRACTED AT 0905 EST ON 3/3/99 BY KEVIN McLAUGHLIN TO FANGIE JONES * * *
The licensee, RG&E, is retracting this event notification. RG&E has confirmed that the Containment Ventilation Isolation (CVI) signal that was generated on 02/27/99 was an invalid actuation and involved only the system equivalent to the reactor building ventilation system. Further evaluation confirmed that the CVI signal was due to a temporary electrical jumper that was connected, but did not make adequate electrical contact with the terminal board. The CVI was not in response to any radiation condition.
The NRC Resident Inspector was notified of this retraction by the licensee.
The NRC Headquarters Operations Officer notified the R1DO (Michael Modes).
"During Instrument and Control (I/C) activities on radiation channel R-12, an unexpected Containment Ventilation Isolation (CVI) occurred. The planning activities for this maintenance recognized the potential of generating a CVI signal and directed the technicians to install a jumper to prevent the actuation. Even with the jumper installed an unexpected CVI occurred when the R-12 drawer was deenergized. The CVI was therefore due to maintenance activities and was not the result of an actual high radiation condition.
"No plant system other than the containment ventilation monitoring system was affected by this event. The plant is stable at approximately 70% power with a plant coastdown in progress.
"This event is reportable under lOCFR50.72(b)(2)(ii), 'Any condition that results in a manual or automatic actuation an Engineered Safety Feature.'"
The NRC resident inspector has been informed of this notification.
* * * RETRACTED AT 0905 EST ON 3/3/99 BY KEVIN McLAUGHLIN TO FANGIE JONES * * *
The licensee, RG&E, is retracting this event notification. RG&E has confirmed that the Containment Ventilation Isolation (CVI) signal that was generated on 02/27/99 was an invalid actuation and involved only the system equivalent to the reactor building ventilation system. Further evaluation confirmed that the CVI signal was due to a temporary electrical jumper that was connected, but did not make adequate electrical contact with the terminal board. The CVI was not in response to any radiation condition.
The NRC Resident Inspector was notified of this retraction by the licensee.
The NRC Headquarters Operations Officer notified the R1DO (Michael Modes).