Event Notification Report for January 03, 1999
U.S. Nuclear Regulatory Commission
Operations Center
EVENT REPORTS FOR
01/02/1999 - 01/03/1999
Power Reactor
Event Number: 35213
Facility: COMANCHE PEAK
Region: 4 State: TX
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: STEVEN SEWELL
HQ OPS Officer: FANGIE JONES
Region: 4 State: TX
Unit: [] [2] []
RX Type: [1] W-4-LP,[2] W-4-LP
NRC Notified By: STEVEN SEWELL
HQ OPS Officer: FANGIE JONES
Notification Date: 01/03/1999
Notification Time: 13:54 [ET]
Event Date: 01/03/1999
Event Time: 11:15 [CST]
Last Update Date: 01/03/1999
Notification Time: 13:54 [ET]
Event Date: 01/03/1999
Event Time: 11:15 [CST]
Last Update Date: 01/03/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
10 CFR Section:
50.72(b)(2)(ii) - ESF ACTUATION
Person (Organization):
CHARLES MARSCHALL (R4)
CHARLES MARSCHALL (R4)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 2 | M/R | Y | 100 | Power Operation | 0 | Hot Standby |
MANUAL REACTOR TRIP DUE TO TURBINE CONTROL SYSTEM MALFUNCTION
The licensee reported that the turbine control system instantaneously reduced turbine load from 1161 MWe to about 200 MWe for an unknown reason. Multiple steam generator alarms were received, control rods began inserting, and the steam dumps opened in response to the turbine load decrease. Pressurizer relief valve PCV-455A opened momentarily due to the pressure transient. The reactor was manually tripped, all rods fully inserted, and the auxiliary feedwater pumps, both motor and steam turbine driven, started and restored steam generator level in all steam generators. The unit is stable in Mode 3, Hot Standby. All safety systems responded as expected and restart will be evaluated after further investigation of the cause of the event.
The licensee notified the resident inspector.
The licensee reported that the turbine control system instantaneously reduced turbine load from 1161 MWe to about 200 MWe for an unknown reason. Multiple steam generator alarms were received, control rods began inserting, and the steam dumps opened in response to the turbine load decrease. Pressurizer relief valve PCV-455A opened momentarily due to the pressure transient. The reactor was manually tripped, all rods fully inserted, and the auxiliary feedwater pumps, both motor and steam turbine driven, started and restored steam generator level in all steam generators. The unit is stable in Mode 3, Hot Standby. All safety systems responded as expected and restart will be evaluated after further investigation of the cause of the event.
The licensee notified the resident inspector.
Power Reactor
Event Number: 35222
Facility: HADDAM NECK
Region: 1 State: CT
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: RICHARD WILLIS
HQ OPS Officer: LEIGH TROCINE
Region: 1 State: CT
Unit: [1] [] []
RX Type: [1] W-4-LP
NRC Notified By: RICHARD WILLIS
HQ OPS Officer: LEIGH TROCINE
Notification Date: 01/06/1999
Notification Time: 12:07 [ET]
Event Date: 01/03/1999
Event Time: 16:00 [EST]
Last Update Date: 01/06/1999
Notification Time: 12:07 [ET]
Event Date: 01/03/1999
Event Time: 16:00 [EST]
Last Update Date: 01/06/1999
Emergency Class: NON EMERGENCY
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
10 CFR Section:
50.72(b)(2)(vi) - OFFSITE NOTIFICATION
Person (Organization):
WILLIAM COOK (R1)
JOSEPHINE PICCONE/EO (NMSS)
FEMA, DOE, DOA, HHS (FAX)
EPA, DOT/NAT RSP CTR (FAX)
WILLIAM COOK (R1)
JOSEPHINE PICCONE/EO (NMSS)
FEMA, DOE, DOA, HHS (FAX)
EPA, DOT/NAT RSP CTR (FAX)
| Unit | SCRAM Code | RX Crit | Initial PWR | Initial RX Mode | Current PWR | Current RX Mode |
|---|---|---|---|---|---|---|
| 1 | N | N | 0 | Decommissioned | 0 | Decommissioned |
OFFSITE NOTIFICATION REGARDING 1,600 GALLONS OF STORM WATER THAT LEAKED FROM THE WASTE WATER HOLDUP TANK DIKE AREA FOLLOWING HEAVY RAINS
The following text is a portion of a facsimile received from the licensee:
"During a heavy rainfall, storm water accumulated in the [waste water holdup tank] dike area faster than the dike area sump pump could drain it. A portion of the storm water (approximately 1,600 gallons) then leaked through cracks in the dike [area wall at approximately 1600 on 01/03/99]. The water contained approximately 233 µCi (microcuries) H3, 2 µCi (microcuries) Co-60, and 6 µCi (microcuries) Cs-137. These values are approximately 1/1,000,000 of the 40 CFR [Part] 302 reportable quantities."
"This event is similar to events reported on 10/01/98 and 12/01/98." (Refer to event numbers 34861 and 35106, respectively.)
"Corrective actions are being evaluated."
The licensee determined that this event was reportable at 1145 today (01/06/98). At approximately 1200 today (01/06/99), the licensee notified the Connecticut Department of Environmental Protection that this storm water leaked from the dike area onto the ground (inside the protected area).
There is no NRC resident inspector assigned to this site.
The following text is a portion of a facsimile received from the licensee:
"During a heavy rainfall, storm water accumulated in the [waste water holdup tank] dike area faster than the dike area sump pump could drain it. A portion of the storm water (approximately 1,600 gallons) then leaked through cracks in the dike [area wall at approximately 1600 on 01/03/99]. The water contained approximately 233 µCi (microcuries) H3, 2 µCi (microcuries) Co-60, and 6 µCi (microcuries) Cs-137. These values are approximately 1/1,000,000 of the 40 CFR [Part] 302 reportable quantities."
"This event is similar to events reported on 10/01/98 and 12/01/98." (Refer to event numbers 34861 and 35106, respectively.)
"Corrective actions are being evaluated."
The licensee determined that this event was reportable at 1145 today (01/06/98). At approximately 1200 today (01/06/99), the licensee notified the Connecticut Department of Environmental Protection that this storm water leaked from the dike area onto the ground (inside the protected area).
There is no NRC resident inspector assigned to this site.