The U.S. Nuclear Regulatory Commission is in the process of rescinding or revising guidance and policies posted on this webpage in accordance with Executive Order 14151 Ending Radical and Wasteful Government DEI Programs and Preferencing, and Executive Order 14168 Defending Women From Gender Ideology Extremism and Restoring Biological Truth to the Federal Government. In the interim, any previously issued diversity, equity, inclusion, or gender-related guidance on this webpage should be considered rescinded that is inconsistent with these Executive Orders.

Health Physics Questions and Answers - Question 108

Question 108: Can the surveys of radiographic exposure devices performed under 10 CFR 34.43 (b) and (c) be used to show compliance with 10 CFR 20.1906 (f)? If so, is it sufficient to document the survey once, to satisfy both requirements?

Answer: The survey performed to show compliance with 10 CFR 34.43 (c) can be used to show compliance with 10 CFR 20.1906 (f). It is sufficient to document the survey results one time.

The survey performed to show compliance with 20 CFR 34.43 (b) cannot be used to show compliance with 10 CFR 29.1906 (f). The purpose of the survey performed under 10 CFR 20.1906 (f) is to ensure the radioactive source is still properly lodged in its shield after transport.

(Reference: 10 CFR 20.1906 (f), 34.43 (b), and 34.43 (c)).