Home > NRC Library > ADAMS Public Documents
Partial response to FOIA request for seven categories of info.Forwards documents listed in App A.Documents 1 & 2 already in PDR.App B documents available in PDR.LPDR profiles for Ginna & Indian Point 3 encl.
Accession Number: ML20070J834
Date Released: Saturday, November 7, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20070J826 - Partial response to FOIA request for seven categories of info.Forwards documents listed in App A.Documents 1 & 2 already in PDR.App B documents available in PDR.LPDR profiles for Ginna & Indian Point 3 encl. (7 page(s), 11/30/1982)
- ML20070K030 - IE Insp Rept 50-261/75-14 on 751104-19.Noncompliances noted: failure to follow procedures for radiation surveys/maint of instrument records & surveillance testing procedures did not provide for recording "as-found" & "as-left" calibr data. (17 page(s), 12/16/1975)
- ML20070K018 - Responds to NRC 751211 ltr re violations noted in IE Insp Rept 50-261/75-14.Corrective actions:quarterly calibr of survey instruments will be performed per Health Physics Procedure HP-11 by 760131 & Procedure HP-1 will be revised. (4 page(s), 1/5/1976)
- ML20070J951 - Forwards IE Insp Repts 50-250/75-07 & 50-251/75-07 on 750512-14.Deviation from FSAR commitment observed.Licensee requested to inform NRC of plans for implementing FSAR commitment. (1 page(s), 5/27/1975)
- ML20070J850 - Forwards SER input (Task 82-05) re steam generator matl accountability controls at facility.Matl accountability controls used during 1982 steam generator mods included major improvements over controls used in 1975. (5 page(s), 5/19/1982)
- ML20070J943 - Forwards IE Insp Repts 50-250/75-16 & 50-251/75-16 on 751105-21.Noncompliance noted. (2 page(s), 12/9/1975)
- ML20070J876 - IE Insp Repts 50-250/75-08 & 50-251/75-08 on 750527-30. Noncompliance noted:failure to use latest approved procedure in performance of surveillance test. (15 page(s), 6/24/1975)
- ML20070J996 - IE Insp Repts 50-250/75-17 & 50-251/75-17 on 751209-12 & 16-19.Noncompliance noted:high radiation area improperly barricaded & licensed operator requalification program not fully performed per Administrative Procedure 0301. (18 page(s), 1/12/1976)
- ML20070J932 - Responds to NRC 751209 ltr re violation noted in IE Insp Repts 50-250/75-16 & 50-251/75-16.Corrective actions:overdue inservice insp rept transmitted to NRC on 751120 & procedure written to describe scheduling & preparation of repts. (2 page(s), 12/29/1975)
- ML20070J983 - Responds to NRC 760113 ltr re violations noted in IE Insp Repts 50-250/75-17 & 50-251/75-17.Corrective actions:drums of radwaste properly barricaded & all licensed operators will be brought up to date w/requalification quiz schedule. (5 page(s), 2/2/1976)
- ML20070K022 - Forwards IE Insp Rept 50-261/75-14 on 751104-19. Noncompliance noted. (2 page(s), 12/11/1975)
- ML20070J921 - Ack receipt of 750620 ltr informing NRC of steps taken to correct deviation noted in IE Insp Repts 50-250/75-07 & 50-251/75-07. (1 page(s), 7/21/1975)
- ML20070J967 - IE Insp Repts 50-250/75-07 & 50-251/75-07 on 750512-14. Deviation observed:one tray of control cables in Unit 3 control rod drive room & cable trays exiting auxiliary bldg did not have fire stops installed. (9 page(s), 5/27/1975)
- ML20070J929 - Responds to NRC 750529 ltr re deviation noted in IE Insp Repts 50-250/75-07 & 50-251/75-07.Corrective actions:fire stops installed in cable trays in Unit 4 control rod drive room & entrance to auxiliary bldg above main corridor doors. (2 page(s), 6/20/1975)
- ML20070J990 - Forwards IE Insp Repts 50-250/75-17 & 50-251/75-17 on 751209-12 & 16-19.Noncompliance noted. (2 page(s), 1/13/1976)
- ML20070K041 - Responds to NRC 761021 ltr re violation noted in IE Insp Repts 50-280/76-14 & 50-281/76-14.Corrective actions: Administrative Procedure 29 redistributed & importance of proper documentation practices emphasized. (4 page(s), 12/6/1976)
- ML20070K052 - IE Insp Repts 50-280/76-14 & 50-281/76-14 on 760915-17. Noncompliance noted:failure to follow log book entry & review & initial requirements specified in Administrative Procedure 29. (13 page(s), 10/19/1976)
- ML20070J925 - Ack receipt of 751229 ltr informing NRC of steps taken to correct violation noted in IE Insp Repts 50-250/75-16 & 50-251/75-16. (1 page(s), 1/5/1976)
- ML20070K034 - Ack receipt of 761206 ltr informing NRC of steps taken to correct violation noted in IE Insp Repts 50-280/76-14 & 50-281/76-14. (1 page(s), 1/14/1977)
- ML20070J955 - IE Insp Repts 50-250/75-16 & 50-251/75-16 on 751105-21. Noncompliance noted:failure to submit Unit 4 inservice insp rept to NRC within 90 days. (17 page(s), 12/5/1975)
- ML20070J975 - Forwards listed documents re IE Insp Rept 50-261/75-15. Documents filed in LPDR. (1 page(s), 1/21/1976)
- ML20070J985 - Ack receipt of IE Insp Rept 50-261/75-15 on 751124-25.No proprietary info. (1 page(s), 1/14/1976)
- ML20070K004 - Forwards listed documents re IE Insp Rept 50-261/75-14. Documents filed in LPDR. (1 page(s), 1/13/1976)
- ML20070J853 - Responds to NRC 750625 ltr re violation noted in IE Insp Repts 50-250/75-08 & 50-251/75-08.Corrective actions: superseded procedures for surveillance testing removed & latest revision placed in control room on 750526. (3 page(s), 7/14/1975)
- ML20070J887 - Forwards listed documents re IE Insp Repts 50-250/75-07 & 50-251/75-07.Documents filed in LPDR. (1 page(s), 7/21/1975)
- ML20070J964 - Forwards listed documents re IE Insp Repts 50-250/75-17 & 50-251/75-17.Documents filed in LPDR. (1 page(s), 2/13/1976)
- ML20070J972 - Ack receipt of 760202 ltr informing NRC of steps taken to correct violations noted in IE Insp Repts 50-250/75-17 & 50-251/75-17. (1 page(s), 2/13/1976)
- ML20070J864 - Forwards IE Insp Repts 50-250/75-08 & 50-251/75-08 on 750527-30.Noncompliance noted. (2 page(s), 6/25/1975)
- ML20070K000 - IE Insp Rept 50-261/75-15 on 751124-25.No noncompliance noted.Major areas inspected:inservice insp results & procedures & eddy current insp of steam generator tubes. (6 page(s), 12/19/1975)
- ML20070J896 - RO 76-05:on 760915,pressurizer level fell below 45% level setpoint,resulting in decreases of pressurizer pressure & vol control tank level.Caused by leaking tube in steam generator A.Cause of tube failure will be evaluated. (15 page(s), 9/29/1976)
- ML20070J858 - RO 76-12:on 760909,low pressure alarm occurred on safety injection accumulator C,resulting in pressure reduction. Caused by partially open HCV 1936 & body to bonnet leaks on HCV 1898 & 1549.Valves repaired & accumulator repressurized. (5 page(s), 10/1/1976)
- ML20070J904 - Forwards listed documents re IE Insp Repts 50-250/75-16 & 50-251/75-16.Documents filed in LPDR. (1 page(s), 1/5/1976)
- ML20070J940 - Forwards IE Insp Repts 50-250/75-07 & 50-251/75-07 on 750512-14.Deviation from FSAR commitment observed. (2 page(s), 5/29/1975)
- ML20070J993 - Forwards IE Insp Rept 50-261/75-15 on 751124-25.No noncompliance noted. (2 page(s), 12/24/1975)
- ML20070J868 - RO 76-13:on 760916,normal boric acid makeup to vol control tank could not be accomplished due to plugging of chemical & vol control sys line 1-inch-CH-56-152.Cause unknown.Line will be inspected for indications of solidification. (5 page(s), 10/20/1976)
- ML20070K048 - Forwards IE Insp Repts 50-280/76-14 & 50-281/76-14 on 760915-17.Noncompliance noted. (2 page(s), 10/21/1976)
- ML20070J845 - Ack receipt of 750714 ltr informing NRC of steps taken to correct violation noted in IE Insp Repts 50-250/75-08 & 50-251/75-08. (1 page(s), 8/1/1975)
- ML20070K012 - Ack receipt of 760105 ltr informing NRC of steps taken to correct violations noted in IE Insp Rept 50-261/75-14. (1 page(s), 1/13/1976)
- ML20070J880 - RO 76-07:on 760913,monthly average of gaseous & airborne particulate wastes for previous 12 months found greater than Tech Spec limit.Caused by interpretational changes in Tech Spec Section 3.11.B.New limit approved. (5 page(s), 9/24/1976)