Home > NRC Library > ADAMS Public Documents
Forwards LERs 82-093/03L-0,82-054/03L-0 & 82-092/03L-0.
Accession Number: ML20065H338
Date Released: Thursday, March 19, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20065H335 - Forwards LERs 82-093/03L-0,82-054/03L-0 & 82-092/03L-0. (1 page(s), 9/27/1982)
- ML20065H359 - LER 82-093/03L-0:on 820904,at 100% power,air bank 1 for emergency diesel generator 1 found w/insufficient air pressure to start generator.Caused by failure to reset local low air pressure.Bottles filled to 200 psi. (2 page(s), 9/27/1982)
- ML20065H374 - LER 82-054/03L-0:on 820905,unattended portable pump in use to clean waterbox C swung around & flooded svc water pit containing svc water.Valve MOV-SW-202B grounded in open position.Caused by operator error.MOV-SW-202B dried. (3 page(s), 9/27/1982)
- ML20065H377 - LER 82-092/03L-0:on 820905,at full power,RPI F-8 observed fluctuating up to 15 steps.Caused by exposure of containment side electrical penetration to excessive moisture & faulty signal.Steam leak repaired. (2 page(s), 9/27/1982)