Home > NRC Library > ADAMS Public Documents
Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243.
Accession Number: ML120100495
Date Released: Thursday, January 19, 2012
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML120100494 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 1. Root Cause Evaluation-Service Water Pump P-7C Coupling Failure, Rev 0, Part 1 of 7. (Cover letter with attachments). (53 page(s), 1/5/2012)
- ML120100496 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 1. Root Cause Evaluation-Service Water Pump P-7C Coupling Failure, Rev 0, Part 2 of 7. (25 page(s), 1/5/2012)
- ML120100499 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 1. Root Cause Evaluation-Service Water Pump P-7C Coupling Failure, Rev 0, Part 2.2 of 7. (25 page(s), 1/5/2012)
- ML120100503 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 1. Root Cause Evaluation-Service Water Pump P-7C Coupling Failure, Rev 0, Part 2.3 of 7. (25 page(s), 1/5/2012)
- ML120100506 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 1. Root Cause Evaluation-Service Water Pump P-7C Coupling Failure, Rev 0, Part 2.4 of 7. (26 page(s), 1/5/2012)
- ML120100509 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 2. SDP Assessment of Service Water Pump P-7C Coupling Failures, Part 2 of 7 Completed. (39 page(s), 1/5/2012)
- ML120100511 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 2. SDP Assessment of Service Water Pump P-7C Coupling Failures, Part 4.1 of 7. (41 page(s), 1/5/2012)
- ML120100514 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 2. SDP Assessment of Service Water Pump P-7C Coupling Failures, Part 4.2 of 7. (40 page(s), 1/5/2012)
- ML120100515 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 2. SDP Assessment of Service Water Pump P-7C Coupling Failures, Part 4.3 of 7. (40 page(s), 1/5/2012)
- ML120100516 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 2. SDP Assessment of Service Water Pump P-7C Coupling Failures, Part 4.4 of 7. (33 page(s), 1/5/2012)
- ML120100540 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 2. SDP Assessment of Service Water Pump P-7C Coupling Failures, Part 5.1 of 7. (41 page(s), 12/5/2011)
- ML120100544 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 2. SDP Assessment of Service Water Pump P-7C Coupling Failures, Part 5.2 of 7. (40 page(s), 1/5/2012)
- ML120100546 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 2. SDP Assessment of Service Water Pump P-7C Coupling Failures, Part 5.3 of 7. (44 page(s), 1/5/2012)
- ML120100547 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 2. SDP Assessment of Service Water Pump P-7C Coupling Failures, Part 6.1 of 7. (45 page(s), 1/5/2012)
- ML120100548 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 2-End and Attachment 3, Root Cause Evaluation-Plant Trip During Panel ED-11-2 Maintenance, Rev 2, Part 6.2 of 7. (48 page(s), 1/5/2012)
- ML120100550 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 3, Root Cause Evaluation-Plant Trip During Panel ED-11-2 Maintenance, Rev 2, Part 6.3 of 7. (58 page(s), 1/5/2012)
- ML120100552 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 3, Root Cause Evaluation-Plant Trip During Panel ED-11-2 Maintenance, Rev 2, Part 6.4 of 7. (56 page(s), 1/5/2012)
- ML120100558 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 3, Root Cause Evaluation-Plant Trip During Panel ED-11-2 Maintenance, Rev 2, Part 7.1 of 7. (38 page(s), 1/5/2012)
- ML120100559 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 3, Root Cause Evaluation-Plant Trip During Panel ED-11-2 Maintenance, Rev 2, Part 7.2 of 7. (46 page(s), 1/5/2012)
- ML120100560 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 3, Root Cause Evaluation-Plant Trip During Panel ED-11-2 Maintenance, Rev 2, Part 7.3 of 7. (49 page(s), 1/5/2012)
- ML120100562 - Palisades, Regulatory Conference Supporting Documentation for Apparent Violations EA-11-241 and EA-11-243, Attachment 3, Root Cause Evaluation-Plant Trip During Panel ED-11-2 Maintenance, Rev 2 - End, Part 7.4 of 7. (31 page(s), 1/5/2012)