Home > NRC Library > ADAMS Public Documents
Davis-Besse, Response to Requests for Additional Information Related to Alternative Dissimilar Metal Weld Repair Methods.
Accession Number: ML093360333
Date Released: Thursday, December 10, 2009
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML093360323 - Davis-Besse, Response to Requests for Additional Information Related to Alternative Dissimilar Metal Weld Repair Methods. (128 page(s), 11/23/2009)
- ML093360324 - Calculation, 0800368.301, Rev 0, "Material Properties for Davis-Besse Unit 1, RCP Suction, RCP Discharge, Cold Leg Drain and Core Flood Nozzles Preemptive Weld Overlay Repairs." (50 page(s), 4/21/2009)
- ML093360325 - Calculation, 0800368.311, Rev. 0, "Design Loads for the 28" I.D. Reactor Coolant Pump (RCP) Suction and Discharge Nozzles." (9 page(s), 4/8/2009)
- ML093360326 - Calculation, 0800368.320, Rev. 1, "Optimized Weld Overlay Sizing for the 28" I.D. Outlet/Discharge Reactor Coolant Pump Nozzle." (42 page(s), 5/27/2009)
- ML093360327 - Calculation, 0800368.322, Rev. 1, "Finite Element Models of the Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair." (21 page(s), 5/22/2009)
- ML093360328 - Calculation, 0800368.323, Rev. 1, "Thermal and Unit Mechanical Stress Analyses for Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair." (31 page(s), 5/23/2009)
- ML093360329 - Calculation, 0800368.324, Rev. 0, "Residual Stress Analysis of Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair." (28 page(s), 7/10/2009)
- ML093360330 - Calculation, 0800368.325, Rev. 0, "ASME Code, Section III Evaluation of Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair." (29 page(s), 11/23/2009)
- ML093360331 - Calculation, 0800368.326, Rev. 0, "Crack Growth Evaluation of Reactor Coolant Pump Discharge Nozzle with Weld Overlay Repair." (33 page(s), 7/20/2009)
- ML093360332 - Calculation, 0800777.309, Rev. 0, "Sensitivity Study of Temperbead Surface Area Limitations for Large Bore Weld Overlay Repairs Over Ferritic Materials (from 500 to 1,000 Square Inches)." (29 page(s), 11/2/2009)