Home > NRC Library > ADAMS Public Documents
Forwards response to NRC 830110 Question 210.122 re design documentation for Class 2 & 3 piping sys.Table re guidelines for design & application of branch outlets - shop & field fabrication encl.
Accession Number: ML20069G907
Date Released: Monday, March 23, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20069G905 - Forwards response to NRC 830110 Question 210.122 re design documentation for Class 2 & 3 piping sys.Table re guidelines for design & application of branch outlets - shop & field fabrication encl. (9 page(s), 3/23/1983)
- ML20069G932 - Rev 5 to "Allowable Design Pressures for Various Branch Connection Configurations To Be Used in ASME Section III Class 1 Piping of Catawba Nuclear Power Station." (19 page(s), 2/24/1982)
- ML20069G965 - Rev 1 to "Catawba 1 & 2,Procedure for Selection of Type of Piping Branch Connection,Duke Classes B,C,E,F,G." (16 page(s), 8/19/1981)
- ML20069H002 - Rev 2 to "CL1BIC Computer Program for ASME Section III Class 1 Area Reinforcement Analysis for Certain Branch Connection Types of Catawba Nuclear Power Station." Certifications of engineering calculations encl. (203 page(s), 3/22/1978)