- ML20065Q096 - Forwards LERs 82-054/03L-0;82-055/03L-0,82-039/03L-0 & 82-040/03L-0. (1 page(s), 10/18/1982)
- ML20065Q123 - LER 82-054/03L-0:on 820920,flow transmitter FT-497 failed low.Caused by failure of NLP printed circuit card in 7300 process control sys.Card replaced & instrumentation loop associated w/transmitter returned to svc. (1 page(s), 10/18/1982)
- ML20065Q136 - LER 82-055/03L-0:on 820921,train B chlorine detector declared inoperable due to nonadvancing detector tape.Caused by faulty tape drive motor.Motors & light diffusion disc replaced. (1 page(s), 10/18/1982)
- ML20065Q162 - LER 82-039/03L-0:on 820919,svc water to component cooling water HX 2C isolated.Caused by dislodged pin holding worm drive gear allowing differential pressure across valve disc to close valve.Pin reinstalled & secured. (1 page(s), 10/18/1982)
- ML20065Q182 - LER 82-040/03L-0:on 820919,loss-of-voltage protection channel associated w/B2F sequencer phase 2-3 declared inoperable.Caused by failure of loss-of-voltage relay 27XF1 during testing.Relay cleaned. (1 page(s), 10/18/1982)