Home > NRC Library > ADAMS Public Documents
Forwards LERs 82-084/03L-0,82-085/03L-0,82-086/03L-0, 82-088/03L-0,82-091/03L-0 & 82-092/03L-0.Detailed event analysis submitted.
Accession Number: ML20065B125
Date Released: Thursday, March 19, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20065B122 - Forwards LERs 82-084/03L-0,82-085/03L-0,82-086/03L-0, 82-088/03L-0,82-091/03L-0 & 82-092/03L-0.Detailed event analysis submitted. (2 page(s), 8/31/1982)
- ML20065B136 - LER 82-084/03L-0:on 820801,control element assembly 57 slipped & dropped in excess of Tech Specs.Caused by slow operation of grippers.Control element assembly exercised, oxide deposits removed w/hydrazine & circuits modified. (1 page(s), 8/31/1982)
- ML20065B146 - LER 82-085/03L-0:on 820805,control element assembly 68 slipped & dropped in excess of Tech Specs.Caused by slow operation of grippers.Control element assembly exercised, oxide deposits removed w/hydrazine & circuits modified. (1 page(s), 8/31/1982)
- ML20065B160 - LER 82-086/03L-0:on 820806,control element assembly 38 slipped & dropped in excess of Tech Specs.Caused by slow operation of grippers.Control element assembly exercised, oxide deposits removed w/hydrazine & circuits modified. (1 page(s), 8/31/1982)
- ML20065B169 - LER 82-088/03L-0:on 820806,control element assembly 86 slipped & dropped in excess of Tech Specs.Caused by slow operation of grippers.Control element assembly exercised, oxide deposits removed w/hydrazine & circuits modified. (1 page(s), 8/31/1982)
- ML20065B181 - LER 82-091/03L-0:on 820807,control element assembly 68 slipped & dropped in excess of Tech Specs.Caused by slow operation of grippers.Control element assembly exercised, oxide deposits removed w/hydrazine & circuits modified. (1 page(s), 8/31/1982)
- ML20065B188 - LER 82-092/03L-0:on 820807,control element assembly 77 slipped & dropped in excess of Tech Specs.Caused by slow operation of grippers.Control element assembly exercised, oxide deposits removed w/hydrazine & circuits modified. (1 page(s), 8/31/1982)