Forwards LERs 82-044/03L-0,82-048/03L-0,82-050/03L-0 & 82-035/03L-0.
Accession Number: ML20063N284
Date Released: Tuesday, March 17, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20063N283 - Forwards LERs 82-044/03L-0,82-048/03L-0,82-050/03L-0 & 82-035/03L-0. (1 page(s), 9/13/1982)
- ML20063N286 - LER 82-044/03L-0:on 820814,containment auxiliary personnel hatch declared inoperable.Caused by leakage at hatch shaft seal.Seal replaced,tested & hatch returned to svc. (1 page(s), 9/13/1982)
- ML20063N287 - LER 82-048/03L-0:on 820823,reactor coolant drain tank level control valve failed to close upon receipt of close signal. Cause undetermined.Valve worked when stroked several times subsequent to event. (1 page(s), 9/13/1982)
- ML20063N290 - LER 82-050/03L-0:on 820815,train B chlorine detector declared inoperable due to detector tape not advancing. Caused by sheared pin in paper drive motor.Pin replaced & detector returned to svc. (1 page(s), 9/13/1982)
- ML20063N292 - LER 82-035/03L-0:on 820814,RCS subcooling monitor Channel 1 declared inoperable due to invalid main control board meter readings.Caused by faulty printed circuit card.Card replaced & Channel 1 recalibr & returned to svc. (1 page(s), 9/13/1982)