- ML20033C846 - Forwards LER 81-035/03L-0,LER 81-014/03X-1 & corrected LER 81-015/03X-2. (1 page(s), 11/25/1981)
- ML20033C850 - LER 81-035/03L-0:on 811030,during sampling & analysis of chemical & vol control sys,noted monitor tank indicated total tritium activity exceeded Tech Specs.No cause stated. Liquid transferred to reduce setpoint. (1 page(s), 11/25/1981)
- ML20033C853 - LER 81-014/03X-1:on 810507,during test of presurizer level channels,found transmitter to channel LT 427 out of spec low,implying that high level reactor trip relay would have tripped.Will change transmitters. (1 page(s), 11/25/1981)
- ML20033C860 - Corrected LER,changing rept number from 81-015/03L-2 to 81-015/03X-2.On 810510,during refueling shutdown surveillance test,noted steam flow transmitter out of calibr resulting in trip settings less conservative than Tech Spec. (2 page(s), 11/16/1981)