Discusses resolution of violation re inconsistent correlation between particulate radiation monitors RIA-43 & RIA-47 noted in Insp Repts 50-269/75-01,50-270/75-01 & 50-287/75-01.
Accession Number: ML19322A925
Date Released: Monday, December 2, 2019
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML19322A924 - Discusses resolution of violation re inconsistent correlation between particulate radiation monitors RIA-43 & RIA-47 noted in Insp Repts 50-269/75-01,50-270/75-01 & 50-287/75-01. (1 page(s), 9/18/1975)
- ML19322A926 - Discusses resolution of violation re personnel radiation exposure records noted in IE Insp Repts 50-269/75-01, 50-270/75-01 & 50-287/75-01. (2 page(s), 8/1/1975)
- ML19322A928 - Updates status of resolution of problems w/process radiation monitors for liquid waste,iodine,waste gas & particulates,as identified in IE Insp Repts 50-269/75-01,50-270/75-01 & 50-287/75-01. (2 page(s), 4/30/1975)
- ML19322A929 - Provides addl info re personnel radiation exposure records violation noted in IE Insp Repts 50-269/75-01,50-270/75-01 & 50-287/75-01. (2 page(s), 4/11/1975)
- ML19322A930 - Responds to NRC 750226 ltr re violation noted in IE Insp Repts 50-269/75-01,50-270/75-01 & 50-287/75-01.Corrective actions:leak test to follow administrative controls,maint activities defined & procedure revised for trip setting. (7 page(s), 3/26/1975)