Home > NRC Library > ADAMS Public Documents
Forwards LER 78-014/03X-1,78-018/03X-1 & 78-019/03X-1.
Accession Number: ML093560618
Date Released: Tuesday, June 1, 2010
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML093560617 - Forwards LER 78-014/03X-1,78-018/03X-1 & 78-019/03X-1. (1 page(s), 10/6/1978)
- ML100980087 - LER 78-014/03X-1:on 780523,during low power physics test of high head safety injection pump,leakage confirmed past swing check valve downstream of pump 22.Caused by faulty disc mounting. (2 page(s), 10/6/1978)
- ML100980088 - LER 78-019/03X-1:on 780629,during normal operation,leakage found at socket weld connection on seal injection header downstream of seal injection filters.Caused by pinhole leak. (2 page(s), 10/6/1978)
- ML100980090 - LER 78-018/03X-1:on 780626,during normal operation,slight leak found at valve 1823D in level instrument line from boron injection tank.Caused by crack in bonnet. (2 page(s), 10/6/1978)