RO:on 980819,at 1849 hours reactor room CAM alerted & alarmed,reactor was shutdown.Caused by leak in element 5304. All remaining 8.5 wt% elements have been inspected & all are visually satisfactory.Supporting info,encl.
Accession Number: ML20239A019
Date Released: Wednesday, September 9, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20239A017 - RO:on 980819,at 1849 hours reactor room CAM alerted & alarmed,reactor was shutdown.Caused by leak in element 5304. All remaining 8.5 wt% elements have been inspected & all are visually satisfactory.Supporting info,encl. (28 page(s), 9/1/1998)
- ML20239A020 - Procedure SOP 98-13, "Ventilation of Reactor Room Air Out Stack." (6 page(s), 8/21/1998)
- ML20239A022 - Procedure SOP 98-12, "Insp of Fuel Followed Control Rods & Selected Fuel Elements." (21 page(s), 8/21/1998)