Home > NRC Library > ADAMS Public Documents
Responds to FOIA request for five specified documents. Document 6 not located.Forwards app documents.Documents also available in PDR.Portions of Document 4 withheld (ref FOIA Exemption 4).
Accession Number: ML20154A536
Date Released: Monday, October 28, 2024
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20154A530 - Responds to FOIA request for five specified documents. Document 6 not located.Forwards app documents.Documents also available in PDR.Portions of Document 4 withheld (ref FOIA Exemption 4). (2 page(s), 1/16/1986)
- ML20154A574 - Topical rept evaluation of Suppl 9 to WCAP-8110, "Ice Fallout from Seismic Testing of Fused Ice Baskets." Rept acceptable as ref for specific land-based ice condenser plants under review for license applications. (3 page(s), 11/21/1974)
- ML20154A541 - "Staff Evaluation of Tests Conducted to Demonstrate Functional Adequacy of Ice Condenser Design." (62 page(s), 4/25/1974)
- ML20154A649 - Addendum 1 to WCAP-8282, "Final Rept - Ice Condenser Full- Scale Section Tests at Waltz Mill Facility." (33 page(s), 5/31/1974)
- ML20154A587 - Forwards topical rept evaluation of proprietary WCAP-8336 & nonproprietary Suppl 5 to WCAP-8110, "Ice Condenser Sys Lower Inlet Door Shock Absorber Test Plans & Results." Repts acceptable for referencing in license applications. (2 page(s), 11/3/1975)
- ML20154A554 - Forwards topical rept evaluation of Suppl 9 to WCAP-8110, "Ice Fallout From Seismic Testing of Fused Ice Baskets." Rept adequate for referencing in license applications. (1 page(s), 11/21/1974)
- ML20154A612 - Topical rept evaluation of proprietary WCAP-8336 & nonproprietary Suppl 5 to WCAP-8110, "Ice Condenser Sys Lower Inlet Door Shock Absorber Test Plans & Results." Repts present acceptable design & testing program. (2 page(s), 11/3/1975)