Home > NRC Library > ADAMS Public Documents
Partial response to FOIA request for memos re selection of severity levels for various violations at nuclear plants. Forwards documents listed in App C.Documents also available in PDR.
Accession Number: ML20151G218
Date Released: Monday, June 15, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20153H145 - Partial response to FOIA request for memos re selection of severity levels for various violations at nuclear plants. Forwards documents listed in App C.Documents also available in PDR. (2 page(s), 8/17/1988)
- ML20153H369 - Discusses selection of severity level re containment valve open during operation & inoperable high pressure scram at Univ of Missouri at Columbia research reactor. (2 page(s), 7/21/1981)
- ML20153H506 - Forwards draft documentation re Severity Level III violation.No civil penalty will be assessed since util taking steps to ensure proper dose limits assigned to workers under age of 18. (6 page(s), 8/5/1981)
- ML20153H526 - Documents agreement re proposed course of action per 810902 memo.Based on DOT interpretation matl shipped meets DOT requirements. (1 page(s), 9/14/1981)
- ML20153H497 - Agrees w/regional analysis & conclusion that no civil penalty be issued to util for violations involving excess whole body dose.Draft forwarding ltr,insp rept & notice of violation encl. (6 page(s), 8/14/1981)
- ML20153H199 - Discusses severity of violation of auxiliary feedwater flow restriction at Calvert Cliffs,Unit 1 from 801217-810112. Severity Level IV classification recommended. (2 page(s), 7/15/1981)
- ML20153H423 - Forwards detailed discussion of selection of severity level re disabling all svc water sys on 801209 at Brunswick Unit 2.Citation will be issued on 810316. (3 page(s), 3/10/1981)
- ML20151G381 - Discusses Region 2 selection of severity level re event that violated Tech Specs limiting condition for operation. Agrees w/position as another example of selection of severity level per 810313 memo. (1 page(s), 3/16/1981)
- ML20153H189 - Discusses process for selection of severity level for drywell pressure sensor isolation at Peach Bottom 2. (2 page(s), 7/14/1981)
- ML20153H538 - Supports util denial of Severity Level III violation for punctured drums on basis that shipment met requirements for bulk shipment per 49FR173.392(d).Draft response to util & DOT ltr to util encl. (3 page(s), 9/2/1981)
- ML20153H177 - Discusses selection of Severity Level IV for 810114 loss of heat tracing at Robinson 2.Mitigating circumstances listed. (3 page(s), 2/19/1981)