Home > NRC Library > ADAMS Public Documents
Forwards Insp Rept 99901075/88-01 on 880111-14 & notice of nonconformance.Implementation of QA program failed to meet certain requirements,including instances of inadequate matl control & control of temp gauges used in weld rod ovens.
Accession Number: ML20149M216
Date Released: Monday, October 28, 2024
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20149M215 - Forwards Insp Rept 99901075/88-01 on 880111-14 & notice of nonconformance.Implementation of QA program failed to meet certain requirements,including instances of inadequate matl control & control of temp gauges used in weld rod ovens. (4 page(s), 2/22/1988)
- ML20149M221 - Notice of nonconformance from insp on 880111-14. Nonconformance noted:matl not purchased to ASTM/ASME spec, chemical composition limits incomplete & actual mechanical property limits missing. (2 page(s), 2/22/1988)
- ML20149M233 - Insp Rept 99901075/88-01 on 880111-14.Noncompliances noted. Major areas inspected:welding,procurement,NDE,testing & insp,measuring & testing equipment,noncomforming items, training & audits. (7 page(s), 2/15/1988)