Home > NRC Library > ADAMS Public Documents
Forwards Safety Insp Rept 50-219/87-41 on 871116-20 & notice of violation.Deficiencies uncovered & corrective actions to be taken after necessary rework on torus to drywell vacuum breakers evaluated requested.
Accession Number: ML20149B788
Date Released: Thursday, June 11, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20149B784 - Forwards Safety Insp Rept 50-219/87-41 on 871116-20 & notice of violation.Deficiencies uncovered & corrective actions to be taken after necessary rework on torus to drywell vacuum breakers evaluated requested. (2 page(s), 1/28/1988)
- ML20149B817 - Notice of violation from insp on 871116-1220.Violations noted:two contaiment spray pump suction gauge isolation valves tagged shut found open & w/o RED/WHITE tags & Valves V-3-506,507,513 & 514 found open. (1 page(s), 1/28/1988)
- ML20149B855 - Insp Rept 50-219/87-41 on 871116-1220.Violations noted.Major areas inspected:plant operations & strike-related activities,plant startup,control room observations,fire protection,surveillance testing,maint & event reporting. (21 page(s), 1/28/1988)