Forwards LERs 82-055/03L-0,82-096/03L-0 & 82-095/03L-0.
Accession Number: ML20063P227
Date Released: Tuesday, March 17, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20063P226 - Forwards LERs 82-055/03L-0,82-096/03L-0 & 82-095/03L-0. (1 page(s), 10/4/1982)
- ML20063P232 - LER 82-055/03L-0:on 820906,charging pump auxiliary oil pump A tripped leading to tripping of replacement pump/motor. Auxiliary pump failure caused by open winding in motor. Replacement tripping caused by undersized thermal overloads. (2 page(s), 10/4/1982)
- ML20063P238 - LER 82-096/03L-0:on 820916,w/unit at 99% power,PT-27C revealed that amp readings for heat tracing Panel 9,circuit 19,was below acceptance criteria.Caused by excessive heat. Defective heat tracing replaced & tested. (2 page(s), 10/4/1982)
- ML20063P241 - LER 82-095/03L-0:on 820911,w/unit at full power,steam generator C level indication LI-1-495 drifted high.Caused by body-bonnet leak on transmitter ref leg root valve.Repairs will be performed during next outage. (2 page(s), 10/4/1982)