Forwards updated LER 82-002/03X-1 & LERs 82-024/03L-0 & 82-025/03L-0.
Accession Number: ML20062N394
Date Released: Monday, March 16, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20062N391 - Forwards updated LER 82-002/03X-1 & LERs 82-024/03L-0 & 82-025/03L-0. (1 page(s), 8/13/1982)
- ML20062N408 - Updated LER 82-002/03X-1:on 820114,during normal operation, pressurizer level transmitter LT427 found out of spec.Caused by instrument drift.Transmitter recalibr.Barton transmitters will be changed as part of long-term upgrade. (1 page(s), 8/13/1982)
- ML20062N420 - LER 82-024/03L-0:on 820716,while at full power,overpower delta T channel 3 rod stop alarm observed cycling in & out. Caused by malfunction of TAVG signal conditioner causing channel to drift.Spare signal box installed & calibr. (1 page(s), 8/13/1982)
- ML20062N435 - LER 82-025/03L-0:on 820716,during document review,waste disposal liquid effluent monitor found indicating low.Caused by weak detection tube on monitor.Tube replaced & detector recalibr. (1 page(s), 8/13/1982)