Home > NRC Library > ADAMS Public Documents
Forwards LERs 82-028/03L-0,82-029/03L-0,82-031/03L-0 & 82-024/03L-0.
Accession Number: ML20054M106
Date Released: Sunday, March 8, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20054M105 - Forwards LERs 82-028/03L-0,82-029/03L-0,82-031/03L-0 & 82-024/03L-0. (1 page(s), 6/30/1982)
- ML20054M113 - LER 82-028/03L-0:on 820605,during performance of FNP-1-STP-22.16,turbine driven auxiliary feedwater pump failed to start.Caused by faulty limit switch on valve HV-3226.Limit switch replaced. (1 page(s), 6/30/1982)
- ML20054M116 - LER 82-029/03L-0:on 820605,containment airlock declared inoperable when airlock outer door could not be shut.Caused by broken door shaft.Shaft repaired. (1 page(s), 6/30/1982)
- ML20054M119 - LER 82-031/03L-0:on 820531,surveillance requirement for radiation monitor R-60A not performed per Tech Specs.Caused by personnel error.Surveillance performed.Personnel instructed. (1 page(s), 6/30/1982)
- ML20054M126 - LER 82-024/03L-0:on 820601,containment atmosphere activity monitors R-11 & R-12 declared inoperable when inboard & outboard pumps tripped due to erroneous low flow signal. Caused by setpoint drift.Setpoints adjusted. (1 page(s), 6/30/1982)