Home > NRC Library > ADAMS Public Documents
Forwards LERs 82-027/03L-0,82-057/03L-0,82-058/03L-0 & 82-024/01T-0.
Accession Number: ML20054G165
Date Released: Sunday, March 8, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20054G164 - Forwards LERs 82-027/03L-0,82-057/03L-0,82-058/03L-0 & 82-024/01T-0. (1 page(s), 6/8/1982)
- ML20054G170 - LER 82-027/03L-0:on 820513,performance of PT 27B revealed amp readings for heat tracing panels 8 & 9,circuit 21A,below acceptance criteria.Caused by excessive heat.Defective heat tracing replaced. (2 page(s), 6/8/1982)
- ML20054G172 - LER 82-057/03L-0:on 820515,review of I-131 spike history revealed that deviation repts not submitted for 820106 & 0325 post-reactor trip specific activity samples of RCS w/dose equivalent I-131 higher than Tech Specs. (4 page(s), 6/8/1982)
- ML20054G177 - LER 82-058/03L-0:on 820516,T-26.1 revealed component cooling sys radiation monitor RM-CC-105 reading above alarm setpoint but not alarming.Caused by out of calibr alarm & oscillator cards.Cards calibr. (2 page(s), 6/8/1982)
- ML20054G180 - LER 82-024/01T-0:on 820524,weld leak on A steam generator channel head drain piping at 2-RC-159 identified during RCS integrity test PT-11.Caused by random defect in root weld, possibly due to split pass. (2 page(s), 6/8/1982)