Forwards LERs 82-016/03L-0,82-032/03L-0,82-035/03L-0 & 82-038/03L-0.
Accession Number: ML20053C209
Date Released: Saturday, March 7, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20053C208 - Forwards LERs 82-016/03L-0,82-032/03L-0,82-035/03L-0 & 82-038/03L-0. (1 page(s), 4/2/1982)
- ML20053C223 - LER 82-016/03L-0:on 820303,snubber 2-S1-HSS-20 found inoperable due to low oil reservoir level.Caused by seal leakage.Snubber repaired,tested & reinstalled. (2 page(s), 4/2/1982)
- ML20053C236 - LER 82-032/03L-0:on 820314,accumulator levels increased to maintain Tech Spec level limits.Caused by operator failure to close containment isolation valve 1-SI-32 per OP-7.7. (2 page(s), 4/2/1982)
- ML20053C251 - LER 82-035/03L-0:on 820307,procedure PT-18.7 revealed high vibration from charging pump 1-CH-P-1B which was declared inoperable.Pump 1-CH-P-1B inoperability caused by worn outboard bearing on pump shaft. (2 page(s), 4/2/1982)
- ML20053C261 - LER 82-038/03L-0:on 820307,nuclear power range instrument N-41 & associated delta flux indicator operated erratically. Channel placed in trip mode.Caused by possible detector malfunction or malfunction of detector cable in containment. (2 page(s), 4/2/1982)