Home > NRC Library > ADAMS Public Documents
Forwards LERs 82-046/03L-0,82-052/03L-0 & 82-011/03L-0.
Accession Number: ML20053B679
Date Released: Saturday, March 7, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20053B678 - Forwards LERs 82-046/03L-0,82-052/03L-0 & 82-011/03L-0. (1 page(s), 5/17/1982)
- ML20053B684 - LER 82-046/03L-0:on 820419,process vent particulate radiation monitor filter fault alarm observed.Filter paper unable to advance due to swelling caused by water absorption.Caused by lifting of relief valve RV-GW-107. (3 page(s), 5/17/1982)
- ML20053B688 - LER 82-052/03L-0:on 820428,amplifier for heat tracing panel B,circuit 2B,read below acceptance criteria.Caused by excessive heat.Defective heat tracing replaced & tested. Design change initiated. (2 page(s), 5/17/1982)
- ML20053B692 - LER 82-011/03L-0:on 820430,amplifier heat tracing panel 11, circuit 6A,read below acceptance criteria.Caused by excessive heat.Defective heat tracing replaced & tested. Design change initiated. (2 page(s), 5/17/1982)