Home > NRC Library > ADAMS Public Documents
Forwards LERs 82-021/03L-0,82-049/03L-0,82-051/03L-0 & 82-048/03L-0.
Accession Number: ML20052H447
Date Released: Friday, March 6, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20052H446 - Forwards LERs 82-021/03L-0,82-049/03L-0,82-051/03L-0 & 82-048/03L-0. (2 page(s), 5/14/1982)
- ML20052H455 - LER 82-021/03L-0:on 820415,w/unit operating at steady state 96% power,2 emergency diesel generator found stuck in lower position.Caused by speed control governor being physically stuck in lower position. (2 page(s), 5/14/1982)
- ML20052H463 - LER 82-049/03L-0:on 820419,charging pump svc water pump 1-SW-P-10B found to have zero discharge pressure as result of loss of suction to pump.Caused by increased use of svc water by chillers. (1 page(s), 5/14/1982)
- ML20052H467 - LER 82-051/03L-0:on 820425 & 26,post-reactor specific samples of RCS indicated dose equivalent I-131 level greater than Tech Spec limit.Caused by fuel defects in reactor core.Accelerated sampling frequency implemented. (3 page(s), 5/14/1982)
- ML20052H468 - LER 82-048/03L-0:on 820415,following trip,RCS diluted to boron concentration where critical rod position achieved,if control rods withdrawn in normal sequence,would have been lower than insertion limit for zero power. (3 page(s), 5/14/1982)