Forwards "Test Rept for Proof Leak Testing of GPE Wetwell to Drywell Vacuum Breaker Valve," draft "Reanalysis of LaSalle Wetwell to Drywell Vacuum Breakers Under Pool Swell Loading Conditions" & four oversize drawings.Aperture cards in PDR.
Accession Number: ML20027D716
Date Released: Saturday, October 3, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20027D715 - Forwards "Test Rept for Proof Leak Testing of GPE Wetwell to Drywell Vacuum Breaker Valve," draft "Reanalysis of LaSalle Wetwell to Drywell Vacuum Breakers Under Pool Swell Loading Conditions" & four oversize drawings.Aperture cards in PDR. (3 page(s), 10/28/1982)
- ML20027D723 - "Test Rept for Proof & Leak Testing of GPE Wetwell to Drywell Vacuum Breaker Valve." (31 page(s), 10/26/1982)
- ML20027D724 - First draft "Reanalysis of LaSalle Wetwell to Drywell Vacuum Breakers Under Pool Swell Loading Conditions." (20 page(s), 10/31/1982)
- ML20027D725 - Revision 2 to "Test Spec for Proof & Leak Testing of GPE Wetwell-to-Drywell Vacuum Breaker Valve." (9 page(s), 10/26/1982)
- ML20027D728 - Revision 1 to "Test Plan & Procedure for Proof & Leak Testing of Wetwell to Drywell Vacuum Breaker Valve." (33 page(s), 10/26/1982)
- ML20263R917 - "Drywell/Wetwell Vacuum Breaker Valve Replacement Parts Fabrication Details." Sheet 1 of 1. (1 page(s), 10/20/1982)
- ML20263R926 - "Drywell/Wetwell Vacuum Breaker Valve Compression Ring Assembly Fabrication Details." Sheet 1 of 1. (1 page(s), 10/20/1982)
- ML20263R931 - "Drywell/Wetwell Vacuum Breaker Valve Replacement Parts Test Installation Drawing." Sheet 1 of 1. (1 page(s), 10/20/1982)
- ML20263R939 - "Drywell/Wetwell Vacuum Breaker Valve Replacement Parts Field Installation Drawing." Sheet 1 of 1. (1 page(s), 10/20/1982)