Home > NRC Library > ADAMS Public Documents
Forwards LERs 83-028/03L-0,83-029/03L-0 & 83-030/03L-0.
Accession Number: ML20023B804
Date Released: Thursday, February 6, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20023B803 - Forwards LERs 83-028/03L-0,83-029/03L-0 & 83-030/03L-0. (1 page(s), 4/29/1983)
- ML20023B812 - LER 83-028/03L-0:on 830331,after completion of surveillance test on solid state protection sys train A & review by maint supervisor,sys declared inoperable to troubleshoot possible problem w/safety injection reset time delay. (2 page(s), 4/29/1983)
- ML20023B815 - LER 83-029/03L-0:on 830405,control room access Fire Door 412 would not operate properly.Caused by extension rod being pulled loose from door frame shoe.Shoe set screws replaced & extension rod reinstalled. (1 page(s), 4/29/1983)
- ML20023B819 - LER 83-030/03L-0:on 830402,while on tour,security guard discovered Diesel Room AB cardox sys isolated w/no one in room.Caused by personnel error.Operator instructed on proper procedures for exiting carbon dioxide protected areas. (1 page(s), 4/29/1983)