Home > NRC Library > ADAMS Public Documents
Forwards OP Chopra,JY Lee & FB Litton testimony & RO Meyer, VTH Leung,MB Fields,GA Harrison,JV Nehemias & FB Litton supplemental testimony on issues scheduled for hearing beginning 810601-12.
Accession Number: ML20008F949
Date Released: Sunday, November 8, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20008F948 - Forwards OP Chopra,JY Lee & FB Litton testimony & RO Meyer, VTH Leung,MB Fields,GA Harrison,JV Nehemias & FB Litton supplemental testimony on issues scheduled for hearing beginning 810601-12. (2 page(s), 5/11/1981)
- ML20008F953 - Testimony on Doherty Contentions 10 & 30.Addl diesel generators or changes in Tech Specs unnecessary.Present offsite power sys design adequate & addl diesel generator or shutdown unnecessary.Prof qualifications encl. (15 page(s), 5/11/1981)
- ML20008F957 - Supplemental testimony re Doherty Contentions 14 & 25 on fuel failure detection methods.Detection capability adequate because of low probability of occurrence of inlet flow blockage.Prof qualifications encl. (7 page(s), 5/11/1981)
- ML20008F961 - Supplemental testimony re Doherty Contention 6 on recirculation pump overspeed.Probability of missiles damaging safety-related equipment w/o decoupler on recirculation pump low.Prof qualifications encl. (5 page(s), 5/11/1981)
- ML20008F966 - Supplemental testimony re ASLB Question 8 & Doherty Contention 48 on seismic Category I control rods & control rod drive return line.Portions of control rod drive sys should be designed to Safety Class 1.W/prof qualifications. (7 page(s), 5/11/1981)
- ML20008F973 - Supplemental testimony re ASLB Questions 6 on containment sys & 9 on bypass leakage.Facility meets containment design requirements.Containment atmospheric limits not related to bypass leakage.Prof qualifications encl. (4 page(s), 5/11/1981)
- ML20008F975 - Supplemental testimony re TX PIRG Contention 12 on cable fires.Problem of fast flaming in electrical wires resulting in common mode failures will be resolved.Prof qualifications encl. (4 page(s), 5/11/1981)
- ML20008F978 - Testimony re TX PIRG Contention 30 & McCorkle Contention 17 on charcoal adsorber fires.Prof qualifications encl. (7 page(s), 5/11/1981)
- ML20008F982 - Supplemental testimony re TX PIRG Contention AC 21 on occupational radiation dose.Revisions to estimates of average annual occupational radiation exposure would not damage NRC conclusions.Prof qualifications encl. (10 page(s), 5/11/1981)
- ML20008F985 - Supplemental testimony on TX PIRG Contention 39 on fracture toughness.Facility complies w/requirements.Prof qualifications encl. (5 page(s), 5/11/1981)
- ML20008F989 - Supplemental testimony re Doherty Contention 47 on turbine missiles.Low probability exists of failure of main generator turbine w/generation of missiles resulting in unacceptable damage.Prof qualifications encl. (6 page(s), 5/11/1981)
- ML20008F994 - Testimony re Doherty Contention 50 on jet pump hold down beams.Beams should not crack during life of facility. (5 page(s), 5/11/1981)