Home > NRC Library > ADAMS Public Documents
Responds to 800818 memo re proposed AO classification re reactor coolant pump seal failure.Event did not involve major reduction in degree of public safety & should not be considered AO.
Accession Number: ML19338D883
Date Released: Saturday, November 7, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML19338D882 - Responds to 800818 memo re proposed AO classification re reactor coolant pump seal failure.Event did not involve major reduction in degree of public safety & should not be considered AO. (3 page(s), 8/29/1980)
- ML19338D900 - Forwards draft Commission Paper w/proposed FR notice re failure of reactor coolant pump seal at facility.Event is under consideration as AO,since it satisfies one example in AO policy statement.Requests comment by 800822. (9 page(s), 8/18/1980)
- ML19338D904 - Responds to request for input re proposed AO classification of reactor coolant pump seal failure at facility.Incident more appropriately meets criterion of "Event of Interest." No major breakdown in level of public protection determined. (3 page(s), 8/22/1980)
- ML19338D906 - Operating Reactor Event Memo 80-10,forwarding list of LERs re events which result in containment floor flooding & diagram of RCS.Water on containment floor is only significant during major LOCA. (5 page(s), 7/11/1980)
- ML19338D909 - Repts findings re review of available LER data on reactor coolant pump seal failures.Typical failure modes include inadequate seal spring pressure,design error,thermal shock, personnel error & debris. (3 page(s), 5/2/1980)