Home > NRC Library > ADAMS Public Documents
Forwards addl pages for valve wall thickness verification program,Revision 3,requested in 740612 telcon.Revision 3 documents corrective action for unresolved valve wall thickness Item 72-12/2.
Accession Number: ML19326B720
Date Released: Friday, December 6, 2019
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML19326B719 - Forwards addl pages for valve wall thickness verification program,Revision 3,requested in 740612 telcon.Revision 3 documents corrective action for unresolved valve wall thickness Item 72-12/2. (27 page(s), 6/25/1974)
- ML19326B727 - Forwards valve wall thickness verification program, Revision 3, & QA audit describing corrective action for unresolved item 72-12/2 in response to AEC 720630 & 730216 ltrs.W/o encl. (2 page(s), 5/31/1974)
- ML19326B729 - Forwards Pages 4,4a & Exhibit I as Addendum I to valve wall thickness verification program forwarded in util 731207 ltr. Provides addl info on core flood valves CV-2415 & CV-2419. (5 page(s), 2/1/1974)
- ML19326B732 - Forwards valve wall thickness verification program & QA audit describing corrective action for unresolved item 72-12/2 in response to AEC 720630 & 730702 ltrs.Requests review as resolution of item.W/o encl. (3 page(s), 12/7/1973)
- ML19326B737 - Responds to AEC 720630 ltr re valve wall thickness verification.New code inapplicable.Valves vital to safety within reactor coolant pressure boundary greater than 2 1/2 ft will be verified. (2 page(s), 7/28/1972)