- ML19320A165 - Forwards ROs 50-313/76-15,50-313/76-16 & 50-313/76-18. (1 page(s), 8/3/1976)
- ML19320A168 - RO 50-313/76-15:on 760707,cracked weld discovered in valve CZ-65 heat affected zone.Caused by improper welding during installation.Weld removed & replaced w/3 ft schedule 10 piping. (4 page(s), 8/3/1976)
- ML19320A169 - RO 50-313/76-16:on 760712,sodium thiosulfate tank T-9 found below 37,500 lb Tech Specs limit.Caused by suspected leak into reactor bldg spray sys.Addl sodium thiosulfate (956 lb) added on 760713.Efforts made to reduce leakage. (4 page(s), 8/3/1976)
- ML19320A175 - RO 50-313/76-18:on 760716,hydrogen purge inlet fan,filter bleed valve & penetration room ventilation sys fan breakers tripped.Caused by abnormally hot environ & low thermal overload setting.Overload setting increased & dampers reset. (4 page(s), 8/3/1976)