Home > NRC Library > ADAMS Public Documents
Forwards Insp Rept 50-312/74-02 on 740304,05,11-13,18-20 & 22.Tendon testing technique & test results indicate repeated testing may cause progressive damage.Directorate of Licensing to evaluate generic implications of failure.
Accession Number: ML19309A374
Date Released: Friday, October 25, 2024
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML19309A373 - Forwards Insp Rept 50-312/74-02 on 740304,05,11-13,18-20 & 22.Tendon testing technique & test results indicate repeated testing may cause progressive damage.Directorate of Licensing to evaluate generic implications of failure. (1 page(s), 4/15/1974)
- ML19309A379 - Forwards portion of Insp Rept 50-312/74-02 re inservice insp test on Tendon H50.Progressive tendon damage caused by testing.Test procedures observed not adequate or well thought out. (1 page(s), 3/28/1974)
- ML19309A381 - Forwards Insp Rept 50-312/74-02 on 740304,05,11-13,18-20 & 22.No noncompliance noted. (2 page(s), 4/15/1974)
- ML19309A390 - Insp Rept 50-312/74-02 on 740304,05,11-13,18-20 & 22.No noncompliance noted.Major areas inspected:implementation of QA program for operations,preoperational test results & procedures & radiological & environ protection. (13 page(s), 4/15/1974)