Home > NRC Library > ADAMS Public Documents
Responds to FOIA request for NUREG-0313,results of stress ratio index tests on welds & info re intergranular stress corrosion cracking & performance of weld overlay patches. Forwards App A documents.App B documents available in PDR.
Accession Number: ML19291F219
Date Released: Sunday, November 8, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML20072C752 - Responds to FOIA request for NUREG-0313,results of stress ratio index tests on welds & info re intergranular stress corrosion cracking & performance of weld overlay patches. Forwards App A documents.App B documents available in PDR. (4 page(s), 2/15/1983)
- ML20072C764 - Forwards updated status of indications found in recirculation sys piping at facility. (1 page(s), 8/12/1982)
- ML20071H274 - Summary of 820123 conference call w/util re reactor water cleanup sys pipe cracks. (3 page(s), 1/26/1982)
- ML20072C780 - Discusses degradation & cracking in thick-wall large diameter stainless steel piping at BWR plants per IE Bulletin 82-03 & NRR generic responsibilities.Guidelines for review of pipe crack problem listed. (4 page(s), 12/8/1982)
- ML20072C760 - "Evaluation of 4-Inch Weld Overlay Repair,Quad Cities Unit 2 Reactor Water Cleanup Suction Line." (7 page(s), 2/5/1982)
- ML20072C769 - Agenda for 821014 meeting w/util to review insp program & discuss 22-inch recirculation ring header end cap indications & 12-inch recirculation riser indications. (36 page(s), 10/14/1982)
- ML20072C789 - "Administrative Procedure for Unit Two Reactor Water Cleanup Pipe Repair Upstream of MO-2-1201-2." (16 page(s), 2/15/1983)
- ML20260D584 - "AC Power Routing of Associated Circuits by Fire Zone." Sheet 3A. (1 page(s), 1/8/1982)
- ML20072C756 - "Evaluations of Reactor Water Cleanup Line Repairs,Quad Cities Nuclear Power Station Unit 2." (99 page(s), 1/29/1982)