Home > NRC Library > ADAMS Public Documents
Ack receipt of NRC 781031 ltr & confirms assumption that C-E design processes are considered adequate.No corrective action necessary.
Accession Number: ML19263B662
Date Released: Friday, October 25, 2024
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML19263B661 - Ack receipt of NRC 781031 ltr & confirms assumption that C-E design processes are considered adequate.No corrective action necessary. (1 page(s), 11/20/1978)
- ML19263B663 - Ack receipt of 781005 ltr & requests confirmation whether C-E concludes design processes are adequate.No corrective action necessary. (1 page(s), 10/31/1978)
- ML19263B664 - Responds to 780811 request for addl info re design verification & value mods. (2 page(s), 10/5/1978)
- ML19263B665 - Ack receipt of 780823 ltr informing NRC of steps taken to correct deviations noted in IE Insp Rept 99900401/78-02. (2 page(s), 9/6/1978)
- ML19263B669 - Responds to NRC 780721 ltr re deviations noted in IE Insp Rept 99900401/78-02.Corrective actions:personnel were requalified & reviews redone,procedures were written. Objects to 3 items of deviation. (5 page(s), 8/23/1978)
- ML19263B670 - Forwards IE Insp Rept 99900401/78-02 & Notice of Deviation. (2 page(s), 7/21/1978)
- ML19263B672 - Notice of Deviation from insp on 780627-30. (3 page(s), 7/21/1978)
- ML19263B674 - IE Insp Rept 99900401/78-02 on 780627-30.Noncompliance noted:audits improperly documented & performed,HPIS header valves design inadequate,supplier performance improperly documented. (23 page(s), 7/19/1978)