Home > NRC Library > ADAMS Public Documents
Forwards insp rept 50-255/94-08 on 940510-0630 & notice of violation.Advises that violation of concern because post- modification testing following recent mod to crane failed to detect that interlock bypass keys on control box miswired.
Accession Number: ML18059B112
Date Released: Sunday, November 8, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML18059B111 - Forwards insp rept 50-255/94-08 on 940510-0630 & notice of violation.Advises that violation of concern because post- modification testing following recent mod to crane failed to detect that interlock bypass keys on control box miswired. (4 page(s), 7/20/1994)
- ML18059B113 - Notice of violation from insp on 940510-0630.Violation noted:failure to adequately test spent fuel pool crane L-3, including control box override keys,following design mod. (1 page(s), 7/20/1994)
- ML18059B114 - Insp rept 50-255/94-08 on 940510-0630.Violations noted.Major areas inspected:operational safety verification,NRC restart team,ESFS,onsite event followup,current matl condition, housekeeping & plant cleanliness & radiological controls. (19 page(s), 7/14/1994)