Home > NRC Library > ADAMS Public Documents
Forwards Insp Repts 50-259/90-33,50-260/90-33 & 50-296/90-33 on 901016-1116 & notice of violation.
Accession Number: ML18033B589
Date Released: Sunday, November 8, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML18033B588 - Forwards Insp Repts 50-259/90-33,50-260/90-33 & 50-296/90-33 on 901016-1116 & notice of violation. (10 page(s), 12/17/1990)
- ML18033B590 - Notice of violation from insp on 901016-1116.Violation noted:on 901020, Unit 3 RWCS valve 3-FCV-69-01 unexpectedly isolated during momentary power loss, contrary to Tech Spec 3.11.A.1. (4 page(s), 12/17/1990)