Home > NRC Library > ADAMS Public Documents
Forwards Insp Rept 50-400/89-28 on 891007-1117 & notice of violation.
Accession Number: ML18009A305
Date Released: Saturday, November 7, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML18009A304 - Forwards Insp Rept 50-400/89-28 on 891007-1117 & notice of violation. (5 page(s), 12/8/1989)
- ML18009A306 - Notice of violation from insp on 891007-1117.Violation noted:Engineering Surveillance Test EST-212, "Type C Local Leak Rate Test" incomplete,resulting in injection of borated/contaminated water into instrument air sys. (3 page(s), 12/8/1989)
- ML18009A307 - Insp Rept 50-400/89-28 on 891007-1117.Violation noted.Major areas inspected:plant operations,radiological controls, security,fire protection,surveillance & maint observation, LERs,review of info notices & refueling activities. (16 page(s), 12/7/1989)