Home > NRC Library > ADAMS Public Documents
Informs of intent to use ASME Code Case N409, "Procedure & Personnel Qualification...Piping Welds," as alternate to EPRI program for qualifying NDE personnel.Invocations of Case N409 will be documented in inservice insp records.
Accession Number: ML17055C744
Date Released: Thursday, June 29, 2017
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML17055C743 - Informs of intent to use ASME Code Case N409, "Procedure & Personnel Qualification...Piping Welds," as alternate to EPRI program for qualifying NDE personnel.Invocations of Case N409 will be documented in inservice insp records. (4 page(s), 12/29/1986)
- ML17055C746 - Forwards rept of inservice insp of feedwater nozzles performed during 1986 refueling outage,per requirements of NUREG-0619, "BWR Feedwater Nozzle & CRD Return Line Nozzle Cracking." Visual insp planned for 1990 outage. (2 page(s), 12/23/1986)
- ML17055C747 - "Nine Mile Point Unit 1 Feedwater Nozzle Inservice Insp,1986 Refueling Outage," providing info required by NUREG-0619, "BWR Feedwater Nozzle & CRD Return Line Nozzle Cracking." (32 page(s), 12/23/1986)