Forwards LERs 82-019/03L-0,82-020/03L-0,82-021/03L-0, 82-022/03L-0 & 82-023/03L-0.
Accession Number: ML17053D433
Date Released: Tuesday, March 24, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML17053D432 - Forwards LERs 82-019/03L-0,82-020/03L-0,82-021/03L-0, 82-022/03L-0 & 82-023/03L-0. (2 page(s), 1/12/1983)
- ML17053D434 - LER 82-019/03L-0:on 821213,while performing local leak rate testing,leakage from valves 201-09,201-10,201-31 & 201-32 exceeded Tech Specs.Caused by poor seal design.Vendor mod available & will be completed during current outage. (2 page(s), 1/11/1983)
- ML20070P497 - LER 82-020/03L-0:on 821213,while performing local leak rate testing,leakage from valves 58.1-01 & 58.1-02 exceeded Tech Specs.Caused by valve order.Existing order modified w/check valve followed by gate valve. (1 page(s), 1/11/1983)
- ML20070P513 - LER 82-021/03L-0:on 821215,while performing local leak rate testing,leakage from valves 39-11,39-12,39-13 & 39-14 exceeded Tech Specs.Caused by dry packing condition resulting from current shutdown.Valves will be repacked. (1 page(s), 1/11/1983)
- ML20070P553 - LER 82-022/03L-0:on 821218,while performing local leak rate testing,leakage from valves 201.2-27 & 201.2-28 exceeded Tech Specs.Caused by poor seating resulting from dirt & corrosion.Valves will be cleaned. (1 page(s), 1/11/1983)
- ML20070P601 - LER 82-023/03L-0:on 821218,while performing local leak rate testing,valve 201.2-71 exceeded Tech Specs.Caused by poor seating resulting from dirt & corrosion.Valve will be cleaned followed by retest. (1 page(s), 1/11/1983)