Home > NRC Library > ADAMS Public Documents
DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6
Accession Number: ML14055A128
Date Released: Thursday, March 13, 2014
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML14055A074 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Table of Contents (5 page(s), 2/14/2014)
- ML14055A076 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - List of Tables (21 page(s), 2/14/2014)
- ML14055A077 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - List of Figures (24 page(s), 2/14/2014)
- ML14055A078 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - List of Acronyms (15 page(s), 2/14/2014)
- ML14055A079 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 1 - Introduction and General Description of Plant (185 page(s), 2/14/2014)
- ML14055A080 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Section 02.00 - Introduction (42 page(s), 2/14/2014)
- ML14055A081 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Section 02.01 - Geography and Demography (54 page(s), 2/14/2014)
- ML14055A082 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Section 02.02 - Nearby Industrial, Transportation, and Military Facilities (33 page(s), 2/14/2014)
- ML14055A083 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Section 02.03 - Meteorology and Air Quality (390 page(s), 2/14/2014)
- ML14055A084 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Section 02.04 - Hydrology (237 page(s), 2/14/2014)
- ML14055A085 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Subsection 02.05.01 - Geology, Seismology, and Geotechnical Engineering - Part 01 (185 page(s), 2/14/2014)
- ML14055A087 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Subsection 02.05.01 - Geology, Seismology, and Geotechnical Engineering - Part 02 (40 page(s), 2/14/2014)
- ML14055A089 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Subsection 02.05.02 - Vibratory Ground Motion (193 page(s), 2/14/2014)
- ML14055A090 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Subsection 02.05.03 - Surface Faulting (29 page(s), 2/14/2014)
- ML14055A092 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Subsection 02.05.04 - Stability of Subsurface Materials and Foundations (144 page(s), 2/14/2014)
- ML14055A093 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Subsection 02.05.05 - Stability of Slopes (3 page(s), 2/14/2014)
- ML14055A094 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Appendix 2A (4 page(s), 2/14/2014)
- ML14055A095 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Appendix 2B (1 page(s), 2/14/2014)
- ML14055A096 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Appendix 02.04AA - Wells Within 25 Miles of Fermi 3 (360 page(s), 2/14/2014)
- ML14055A097 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Appendix 02.04BB - Monthly Water Level Maps (17 page(s), 2/14/2014)
- ML14055A098 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Appendix 02.04CC - Raw Slug Test Data (214 page(s), 2/14/2014)
- ML14055A099 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Appendix 02.04DD - Raw Packer Test Data (358 page(s), 2/14/2014)
- ML14055A100 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Appendix 02.05AA - Earthquake Source Catalog (8 page(s), 2/14/2014)
- ML14055A101 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Appendix 02.05BB - Updated Characterization of Large-Magnitude New Madrid Seismic Zone Earthquake Model (1 page(s), 2/14/2014)
- ML14055A103 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Appendix 02.05CC – Updated Characterization Wabash Valley Seismic Zone Model (1 page(s), 2/14/2014)
- ML14055A104 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 02 - Site Characteristics - Appendix 02.05DD - Boring Logs, Monitoring Well Logs, Piezometer Logs, and Text Pit Logs (603 page(s), 2/14/2014)
- ML14055A106 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 03 - Design of Structures, Components, Equipment, and Systems through 3.7.1 (123 page(s), 2/14/2014)
- ML14055A107 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 03 - Design of Structures, Components, Equipment, and Systems - 3.7.2 Seismic System Analysis (111 page(s), 2/14/2014)
- ML14055A108 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 04 - Reactor (2 page(s), 2/14/2014)
- ML14055A109 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 05 - Reactor Coolant System and Connected Systems (9 page(s), 2/14/2014)
- ML14055A110 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 06 - Engineered Safety Features (11 page(s), 2/14/2014)
- ML14055A111 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 07 - Instrumentation and Control Systems (1 page(s), 2/14/2014)
- ML14055A112 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 08 - Electrical Power (16 page(s), 2/14/2014)
- ML14055A113 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 09 - Auxiliary Systems (64 page(s), 2/14/2014)
- ML14055A114 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 10 - Steam and Power Conversion System (12 page(s), 2/14/2014)
- ML14055A115 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 11 - Radioactive Waste Management (27 page(s), 2/14/2014)
- ML14055A116 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 12 - Radiation Protection (68 page(s), 2/14/2014)
- ML14055A119 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 13 - Conduct of Operations (107 page(s), 2/14/2014)
- ML14055A120 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 14 - Initial Test Program (43 page(s), 2/14/2014)
- ML14055A121 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 15 - Safety Analyses (1 page(s), 2/14/2014)
- ML14055A122 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 16 - Technical Specifications (1 page(s), 2/14/2014)
- ML14055A123 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 17 - Quality Assurance through Appendix 17AA - Fermi 3 Policy Quality Assurance During Construction and Operation (37 page(s), 2/14/2014)
- ML14055A124 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 17 - Quality Assurance - Appendix 17AA - Quality Assurance Program Description (81 page(s), 2/14/2014)
- ML14055A125 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 18 - Human Factors Engineering (1 page(s), 2/14/2014)
- ML14055A126 - DTE Energy - Detroit Edison Fermi 3 COLA (Final Safety Analysis Report), Rev. 6 - Chapter 19 - Probabilistic Risk Assessment and Severe Accidents (7 page(s), 2/14/2014)