Home > NRC Library > ADAMS Public Documents
Forwards LER 79-013/01T-0 & 790910 "Preliminary Rept on IE Bulletin 79-17,Insp of Stainless Steel Safety-Related Piping Containing Stagnant,Oxygenated,Borated Water."
Accession Number: ML13316B699
Date Released: Friday, November 6, 2020
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML13316B698 - Forwards LER 79-013/01T-0 & 790910 "Preliminary Rept on IE Bulletin 79-17,Insp of Stainless Steel Safety-Related Piping Containing Stagnant,Oxygenated,Borated Water." (13 page(s), 9/11/1979)
- ML13330A759 - "Preliminary Rept on IE Bulletin 79-17,Insp of Stainless Steel Safety-Related Piping Containing Stagnant,Oxygenated, Borated Water." (9 page(s), 9/10/1979)
- ML13330A760 - LER 79-013/01T-0:on 790906,while penetrant testing pipe per IE Bulletin 79-17,six cracks up to 1 inch long were found in heat affected zone of welds in suction piping to refueling water pumps.Probably caused by chloride stress corrosion. (3 page(s), 9/10/1979)