Home > NRC Library > ADAMS Public Documents
Forwards LERs 80-032/03L-0 & 80-033/03L-0 & updated LER 80-019/03X-2.
Accession Number: ML111661375
Date Released: Thursday, September 1, 2011
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML111661374 - Forwards LERs 80-032/03L-0 & 80-033/03L-0 & updated LER 80-019/03X-2. (2 page(s), 10/24/1980)
- ML111661376 - LER 80-032/03L-0:on 800925,valve plug from RCS loop B bypass valve dislodged & restrictd flow in hot loop of RCS bypass.Caused by failure,through normal use,of mechanical connection between valve plug & stem.Valve replaced. (2 page(s), 10/24/1980)
- ML111661377 - LER 80-033/03L-0:on 801001,during startup operations, condensate water storage tank (CST) level went below Tech Spec limit.Caused by normal water usage during startup. Makeup water sys output increased & tank level normalized. (3 page(s), 10/24/1980)
- ML111661379 - Updated LER 80-019/03X-2:on 800611,during surveillance testing,shield bldg ventilation sys check damper SBV-10A failed to fully open.Caused by instrument drift.SBV-10A controller setpoint adjusted. (1 page(s), 9/26/1980)