Nine Mile Point Response to Request for Additional Information Regarding License Amendment Request for Extended Power Uprate Operation - Reactor System and Health Physics RAI Responses, and Evaluation of Indications in Steam Dryer Hood Support Attachment
Accession Number: ML102170191
Date Released: Monday, July 11, 2011
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML102170184 - Nine Mile Point Response to Request for Additional Information Regarding License Amendment Request for Extended Power Uprate Operation - Reactor System and Health Physics RAI Responses, and Evaluation of Indications in Steam Dryer Hood Support Attachment (28 page(s), 7/30/2010)
- ML102170185 - Attachment 3, Global Nuclear Fuel - Americas, LLC, MCNP01A, Low Enriched UO2 Pin Lattice in Water Critical Benchmark Evaluations Using ENDF/B-V Nuclear Cross-Section Data, Revision 1. (114 page(s), 6/30/2010)
- ML102170186 - Attachment 4, Structural Integrity Associates, Inc., Flaw Evaluation of Indications in the Nine Mile Point Unit 2 Steam Dryer Vertical Support Plates Considering Extended Power Uprate Flow Induced Vibration Loading. (49 page(s), 7/28/2010)
- ML102170295 - Attachment 5, Continuum Dynamics, Inc., CDI Report No. 10-12NP, Design and Stress Evaluation of Nine Mile Point Unit 2 Steam Dryer Modifications for EPU Operation. (91 page(s), 7/30/2010)