Home > NRC Library > ADAMS Public Documents
Forwards RO-76-2-11(B) & RO-76-2-2(B) & updated RO-76-2-3(B) & RO-76-2-10(B).
Accession Number: ML093561075
Date Released: Tuesday, June 1, 2010
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML093561074 - Forwards RO-76-2-11(B) & RO-76-2-2(B) & updated RO-76-2-3(B) & RO-76-2-10(B). (1 page(s), 4/9/1976)
- ML093561076 - RO-76-2-11(B):on 760312,boric acid transfer pump 21 removed from svc to repair leaking seal.Caused by John Crane,type 1, bellow shaft seal leaking due to cracked rotating seal face. Seal was replaced. (1 page(s), 4/9/1976)
- ML093561077 - Updated RO-76-2-2(B):on 760116,bistable trip setting found below limiting safety sys setting.Caused by level controller,Foxboro M/63 alarm unit,w/defective power supply. Board replaced & trip setting adjusted. (1 page(s), 4/9/1976)
- ML093561079 - Updated RO-76-2-3(B):on 760110,bistable became inoperable. Caused by pressure controller Foxboro alarm unit,having defective alarm circuit board & loose fuse chips.Fuse chips tightened. (1 page(s), 4/9/1976)
- ML093561081 - Updated RO-76-2-10(B):on 760315,process radiation monitors R-12 & R-11 became inoperable due to seized Conde sample pump. (1 page(s), 4/9/1976)