Home > NRC Library > ADAMS Public Documents
Browns Ferry, Units 1, 2, and 3 - Technical Specifications (TS) Changes TS-431 and TS-418 - Extended Power Uprate (EPU) - Response to Round 15 Group 4 and Round 17 Request for Additional Information (RAI).
Accession Number: ML081750091
Date Released: Tuesday, July 1, 2008
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML081750080 - Browns Ferry, Units 1, 2, and 3 - Technical Specifications (TS) Changes TS-431 and TS-418 - Extended Power Uprate (EPU) - Response to Round 15 Group 4 and Round 17 Request for Additional Information (RAI). (5 page(s), 6/16/2008)
- ML081750081 - Browns Ferry, Units 1, 2, and 3, Encl. 6, Calculation Package 0006982.301, "Extended Power Uprate Main Steam Line Strain Gage Vibration Monitoring," and Encl. 7, Response to Round 15 Group 4 and Round 17 Request for Additional Information. (143 page(s), 6/16/2008)
- ML081750083 - Browns Ferry, Units 1, 2 & 3, Enclosure 8, CDI Report No. 08-15NP, "Stress Assessment of Browns Ferry Nuclear Unit 1 Steam Dryer and Tie-Bar Modifications," Revision 1. (89 page(s), 6/30/2008)
- ML081750084 - Browns Ferry, Units 1, 2 & 3, Enclosure 9, CDI Report No. 08-04NP, "Acoustic and Low Frequency Hydrodynamic Loads at CLTP Power Level on Browns Ferry Nuclear Unit 1 Steam Dryer to 250 Hz," Revision 1. (154 page(s), 6/30/2008)
- ML081760256 - Browns Ferry, Units 1, 2 & 3, CDI Report No. 08-16NP, "Stress Assessments of Brown Ferry Nuclear Unit 2 Steam Dryer with Tie Bar and Hood Modifications," Revision 0. (2 page(s), 6/30/2008)
- ML081760260 - Browns Ferry, Units 1, 2 & 3, CDI Report No. 08-05NP, "Acoustic and Low Frequency Hydrodynamic Loads at CLTP Power Level on Browns Ferry Nuclear Unit 2 Steam Dryer to 250 Hz with Noise Removed," Revision 2. (34 page(s), 6/30/2008)