Home > NRC Library > ADAMS Public Documents
Salem, Units 1 and 2 - License Change Request S06-010, Steam Generator Feedwater Pump Trip, Feedwater Isolation Valve Response Time Testing and Containment Cooling System.
Accession Number: ML070871102
Date Released: Thursday, April 5, 2007
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML070871105 - Salem, Unit 1 and 2 - License Change Request S06-010, Steam Generator Feedwater Pump Trip, Feedwater Isolation Valve Response Time Testing and Containment Cooling System. (42 page(s), 3/16/2007)
- ML070871106 - Enclosure 1 - WCAP-16503-NP, Revision 3, "Salem Unit 1 and Unit 2 Containment Response to LOCA and MSLB for Containment Fan Cooler Margin Recovery Project." (354 page(s), 2/28/2007)
- ML070871108 - Enclosure 2 - S-C-CBV-MEE-1982, Revision 0, "Updated Containment Pressure/Temperature Response Analysis With SGFP Trip." (56 page(s), 2/19/2007)
- ML070871112 - Calculation 0108-0342-JFL-01, Rev 0, "Analysis of CCW Supply Temperature During LOCA Recirculation." (42 page(s), 2/19/2007)