Home > NRC Library > ADAMS Public Documents
Transmittal of Derived Concentration Guidelines Level (DCGL) and Area Factor Calculations for License Termination Plan (LTP).
Accession Number: ML040280019
Date Released: Friday, December 23, 2005
Package Contents
The following links on this page are to Adobe Portable Document Format (PDF) files. To obtain a free viewer for displaying this format, see our Plugins, Viewers, and Other Tools.
- ML040280024 - Transmittal of Derived Concentration Guidelines Level (DCGL) and Area Factor Calculations for License Termination Plan (LTP). (1 page(s), 1/19/2004)
- ML040280140 - Calculation No. YA-CALC-01-002-03, "Derived Concentration Guideline Levels for Soil at the Yankee Rowe Site." (33 page(s), 1/19/2004)
- ML040280579 - Yankee Rowe Sensitivity Analysis - Soil. Dose Conversion Factor (and Related) Parameter Summary. (66 page(s), 11/26/2003)
- ML040280582 - Probabilistic Results Summary: Yankee Rowe Sensitivity Analysis - Soil. (43 page(s), 11/26/2003)
- ML040280028 - Calculation No. YA-CALC-00-004-03 "Building Surface-Derived Concentration Guideline Levels (DCGL)." (26 page(s), 1/19/2004)
- ML040280583 - RESRAD-BUILD Program Output, Version 3.21. Title: Yankee Rowe DCGL Ag-108m. (142 page(s), 11/29/2003)
- ML040280584 - RESRAD-BUILD Probabilistic Output 3.21. Title: Yankee Rowe DCGL Am-241. (16 page(s), 11/30/2003)
- ML040280031 - Calculation No. YA-CALC-00-005-03, "Building Surface Area Factors." (17 page(s), 1/19/2004)
- ML040280036 - Calculation No. YA-CALC-00-006-03 "Determination of Area Factors for Soil at YNPS Site." (39 page(s), 1/19/2004)
- ML040280040 - Technical Report No. YA-REPT-00-010-03 "Evaluation of the Dose Integration Parameter in RESRAD-BUILD." (15 page(s), 1/12/2004)