skip navigation links 
 
Index | Site Map | FAQ | Facility Info | Reading Rm | New | Help | Glossary | Contact Us blue spacer  
secondary page banner Return to NRC Home Page

Standard Review Plan for In Situ Leach Uranium Extraction License Applications (NUREG-1569)

On this page:

Download complete document

The following links on this page are to documents in Adobe Portable Document Format (PDF). See our Plugins, Viewers, and Other Tools page for more information. For successful viewing of PDF documents on our site please be sure to use the latest version of Adobe.


Publication Information

Manuscript Completed: February 2000
Date Published:
March 2000

Date Completed: June 2003
Date Published:
June 2003

Prepared by:
J. Lusher, NRC Project Manager

Division of Fuel Cycle Safety and Safeguards
Office of Nuclear Material Safety and Safeguards
U.S. Nuclear Regulatory Commission
Washington, DC 20555-0001

Availability Notice


Abstract

A U.S. Nuclear Regulatory Commission source and byproduct materials license is required to recover uranium by in situ leach extraction techniques, under the provisions of Title 10 U.S. Code of Federal Regulations, Part 40 (10 CFR Part 40), “Domestic Licensing of Source Material.” An applicant for a research and development or commercial-scale license, or for the renewal or amendment of an existing license, is required to provide detailed information on the facilities, equipment, and procedures used and an environmental report that discusses the effects of proposed operations on the health and safety of the public and on the environment.

The standard review plan is prepared for the guidance of staff reviewers, in the Office of Nuclear Material Safety and Safeguards, in performing safety and environmental reviews of applications to develop and operate uranium in situ leach facilities. It provides guidance for new license applications, renewals, and amendments. The principal purpose of the standard review plan is to assure the quality and uniformity of staff reviews and to present a well-defined base from which to evaluate changes in the scope and requirements of a review.

The standard review plan is written to cover a variety of site conditions and facility designs. Each section is written to provide a description of the areas of review, review procedures, acceptance criteria, and evaluation findings. However, for a given application, the staff reviewers may select and emphasize particular aspects of each standard review plan section, as appropriate for the application.



Privacy Policy | Site Disclaimer
Wednesday, May 27, 2009